ELK-319DR Wireless Recessed Door Sensor
Description
The ELK-319DR is a Supervised, Wireless Door Sensor
uniquely designed for recess mounting on the inside edge of
a door and its frame. The sensor is virtually invisible when
the door is closed.
As the door is opened or closed, the sensor transmits an
open (trip) or close (restore) signal to the panel. Additionally
transmitted signals include: tamper, hourly supervisory, and
low battery (as needed). The sensor is powered by a single
replaceable 3VDC, lithium battery.
This sensor is compatible with Elk’s 319MHz Receivers/Panels
as well as many other panels that operate on the 319.5MHz
Frequency and adhere to the ITI/Interlogix protocol.
Specifications
RF frequency: 319.5 MHz
Compatibility: ELK-319 Receivers/Panels & other panels
that operate on the 319.5MHz Freq. and
adhere to the ITI/Interlogix protocol
Battery type: 3VDC “CR2” lithium (Panasonic or Varta)
Operating
Temp Range: 32 to 120°F (0 to 49°C)
Storage
Temp Range: -30 to 140°F (-34 to 60°C)
Relative
Humidity:
95% non-condensing
Dimensions 2.25” L x .75” D
Programming (Enrollment)
The following is a general guideline for programming (enrolling)
a sensor into the receiver or panel. For more extensive
instructions please refer to the receiver or panel instructions.
1. Place the panel into the Program mode.
2. Proceed to the WIRELESS SETUP menu.
3. Select the appropriate zone/sensor location number.
4. When prompted by panel to trip the sensor for learning:
• Remove cap from sensor using a coin or screwdriver
• If present pull the battery pull tab out to power the sensor
• The panel should acknowledge the sensor has been learned
by keypad display and/or audio alert (depending on the
panel). If enrollment fails to occur repeat the process
but remove and reinstall the battery OR try pressing and
releasing the tamper plunger.
5. Repeat the above process for any additional wireless
sensors. Proceed to the zone programming to assign each
sensor’s zone definition.
6. Exit programming mode when finished.
Install Magnet in top or side of the door as shown.
Install Sensor door frame (jamb) directly opposite the magnet
Installation Guidelines and Mounting
• This sensor is NOT RECOMMENDED for use with metal
doors or metal jambs as metal will negatively affect the
transmitting range and magnet performance.
• NEVER drill any holes or permanently mount the sensor until
it has been tested at its desired location to make certain it
can be received by the panel.
• Install the sensor within 100 ft. of the receiver or panel.
• The sensor should be mounted in the door frame and the
magnet in the door.
• The selected location must be able to accept an 11/16” hole
to a depth of 2 1/4” for the sensor and 5/8” for the magnet
• The holes must be drilled directly across from each other
to ensure the magnet and sensor operate properly
• Use a 11/16” hole-saw or sharp brad-point drill bit.
• Drill the hole for the magnet first and then drill the hole for the
sensor making certain it is directly across from the magnet.
• Gently press the magnet and sensor into the drilled holes.
DO NOT HAMMER OR FORCE! The magnet and sensor
are slightly larger than the drilled hole to ensure a snug fit.
A small amount of adjustment of the hole may be necessary.
TM
Interlogix is a registered trademark belonging to United Technologies.
All manuals and user guides at all-guides.com