background image

2

 

 

 

Table of Contents

 

 

1.  Read This First  ...................................................................

 

 

2.  Carbon Monoxide – The Silent Killer  ..................................

 

 

3.  Where to Place CO Alarms  ................................................

 

 

4.  Installation  ..........................................................................

 

 

5.  Testing / Monitoring & Maintenance  ....................................

 

 

6.  What to do when the alarm sounds  ....................................

 

 

7.  How to Protect your Family  .................................................

 

 

8.  Technical Specification  ........................................................

 

 

9.  Getting the CO Alarm Serviced  ...........................................

 

 

10.   Warranty  .............................................................................

 

 

11.   Limitations of CO Alarms  ....................................................

 

 

12.   Troubleshooting  ..................................................................

 

 

13.   Display & Indicator Summary  .............................................

 

 

14.   Agency Compliance…………………………………………… 

 

 

page

 

 

3

 

 

4

 

 

9

 

 

15

 

 

17

 

 

21

 

 

22

 

 

24

 

 

25

 

 

25

 

 

26

 

 

28

 

 

29

 

 

31

 

Содержание ELK-6051

Страница 1: ...C 27703 USA Voice 919 381 4235 Certification Exhibit FCC ID TMAELK 6051 IC 4353A 6051 FCC Rule Part 15 247 ISED Canada s Radio Standards Specification RSS 247 T V S D Project Number 72126638 Manufactu...

Страница 2: ...efully for as long as the product is being used It contains vital information on the operation and installation of your Alarm This booklet should be regarded as part of the product If you are just ins...

Страница 3: ...ion 5 Testing Monitoring Maintenance 6 What to do when the alarm sounds 7 How to Protect your Family 8 Technical Specification 9 Getting the CO Alarm Serviced 10 Warranty 11 Limitations of CO Alarms 1...

Страница 4: ...ance particularly rooms where people spend a lot of time e g bedrooms kitchens and sitting rooms In rooms with an appliance install preferably on the ceiling 300mm from walls and between 1 5m to 3m ho...

Страница 5: ...d fuel burning appliances Blocked or cracked chimneys flues Blocked vents or draught proofing which makes areas with fuel burning appliances or fireplaces airtight Engines of cars lawnmowers etc left...

Страница 6: ...and nausea within 20 minutes Death within 1 hour 3 200 Headache dizziness and nausea within 5 10 minutes Death within 25 30 minutes 6 400 Headache dizziness and nausea within 1 2 minutes Death within...

Страница 7: ...0 ppm 2 flashes every 3 secs On within 10 50 minutes typ 30 minutes 250 ppm 3 flashes every 3 secs On within 4 15 minutes typ 9 minutes unless it has alarmed previously see CO Alarm Memory below ppm v...

Страница 8: ...may sound if cigarette smoke is blown into it or aerosols are released nearby CO ALARM MEMORY The CO Alarm memory is an important feature of the CO Alarm where even if the house is unoccupied during...

Страница 9: ...e CO Alarms NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s standard 720 advises as follows Carbon Monoxide Alarms shall be ins...

Страница 10: ...ted is limited the following points should be considered when deciding where best to fit the Alarm s If there is an appliance in a room where people sleep place a CO Alarm in this room Locate a CO Ala...

Страница 11: ...11 300mm CO Alarm 150mm 1 5 to 3 m DEAD AIR DON T LOCATE HERE 1 5 to 3 m Figure 1 Location in room with a fuel burning appliance...

Страница 12: ...about 1 to 2m Figure 2 Location in rooms with sloped ceilings the CO Alarm should be located at the high side of the room Figure 3 Location in bedrooms other rooms remote from the appliance i e at br...

Страница 13: ...by draughts 7 Next to an extractor fan 8 Over heat sources such as radiators or hot air vents 9 Where it would be obstructed e g by curtains or furniture 10 In an area where the temperature could drop...

Страница 14: ...n rooms with sloped ceilings the CO Alarm should be located at the high side of the room see fig 2 3 32 If locating the CO Alarm in a bedroom or in rooms remote from a fuel burning appliance see figur...

Страница 15: ...he Alarm With a pencil mark the location of the two screw holes 4 Taking care to avoid any electrical wiring in the ceiling drill holes using a 5 0mm drill bit through the center of the marked locatio...

Страница 16: ...rm works see figure 5 9 Install all the other Alarms similarly 4 2 How to Tamperproof the Alarm The Alarm can be made resistant to unauthorized removal Break off the small pillar on the base as shown...

Страница 17: ...and the horn will ramp up to full sound to indicate the Alarm is operating correctly Guidelines and best practices for testing are as follows 1 After the system is installed 2 Once weekly thereafter...

Страница 18: ...Off Off On Ramps up to full sound Low Battery Off 1 Flash Off 1 Beep See Note Sensor Fault Off 2 Flashes Off 2 Beeps Replace Unit End of Life EOL Off 3 Flashes Off 3 Beeps Replace Unit Note Replace t...

Страница 19: ...he side wall if it has been exceeded replace the entire unit If the Replace by label on the side wall has not been exceeded remove the Alarm from the mounting plate remove the battery cover see figure...

Страница 20: ...ts mounting plate open the battery door and remove the batteries Dispose in accordance with best practice and guidance on WEEE disposal and recycling Quick Test with Carbon Monoxide The Carbon Monoxid...

Страница 21: ...itch to the OFF position and replace the Alarm on its mounting plate OFF Position ON Position Figure 9 6 What to do when the alarm sounds Warning Actuation of your CO Alarm indicates the presence of c...

Страница 22: ...not been operating in an attached garage or adjacent to the residence Note When ventilation is provided by leaving the window and doors open the CO build up may have dissipated by the time help arrive...

Страница 23: ...including the CO usually through a flue or chimney Ensure chimneys and flues are not blocked or leaking and get them checked every year Check for excessive rust or cracks on appliances and pipe work...

Страница 24: ...Specification Power Two Alkaline AAA type batteries replaceable CO Sensitivity Meets UL2034 Electromagnetic Compatibility Complies with UL2034 FCC Part 15 Test Hush Button Checks electronics and horn...

Страница 25: ...lty materials or workmanship This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unauthorized dismantling or contamin...

Страница 26: ...ide in other areas of the house e g downstairs in a closed room etc but not in the vicinity of the CO Alarm Doors air draughts and obstructions can prevent the CO reaching the Alarm For these reasons...

Страница 27: ...moke Alarms must be fitted to give early warning of fire 7 The CO Alarm does not detect the presence of natural gas methane bottled gas propane butane or other combustible gases Fit combustion Gas Ala...

Страница 28: ...nting plate 4 Replace batteries ALARM SOUNDS FOR NO APPARENT REASON Follow the detailed instructions in Section 6 Entitled What to do when the alarm sounds page 19 If there are still problems 1 Ensure...

Страница 29: ...alarm If the unit continues to sound it is possibly defective and should be replaced see section 9 Getting the CO Alarm Serviced ELK 6051 Indicator Summary Normal Operation Red LED Amber LED Green LE...

Страница 30: ...s Replace Alarm End of Life EOL Press hold button Off 3 flashes 3 beeps with flashes Replace Alarm Alarm Memory Action Red LED Green LED Sounder LCD Display 24 hours after event Flashes as per Table C...

Страница 31: ...ide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wi...

Страница 32: ...le fonctionnement ELK 6051 Wireless CO Detector FCC ID TMAELK 6051 IC 4353A 6051 This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment This equip...

Страница 33: ...Contact Us Customer Service Elk Products Inc 3266 Hwy 70W Connelly Springs NC 28612 Telephone 828 397 4200 web www elkproducts com Elk Products Inc 2017...

Отзывы: