Eliwell ID 400 Скачать руководство пользователя страница 1

PROGRAMMING MENU

To access the Programming menu, hold
the “set” button for more than 5 seconds.

The parameters can be protected by a
PASSWORD (defined by parameter PA) If
the PASSWORD is enabled, the label “PA”
will appear when you access the

Programming Menu

; press the “set” but-

ton and the value “0” will appear; enter
the password using the “UP”/”DOWN” but-
tons and press the “set” button again. This
allows you access to the parameters. The
first that appears is “dF”. 
Use the “UP” and “DOWN” buttons to

scroll through the parameters. When you
reach the one you want to change, press
the “set” button and set the required
value using the “UP” and “DOWN” but-
tons. To store the new parameter value,
press the “set” button.

NOTE

: We strongly recommend that you

switch the instrument off and on again
each time parameter configuration is
changed in order to prevent malfunction-
ing of the configuration and/or ongoing
timings 

(compulsory for selection of

probe type and count parameters).

Setting the set point

If you press the ‘set’ button and release it
immediately, the set point value can be
selected using the UP’ and ‘DOWN’ buttons.
Press and release the ‘set’ button again or
press the ‘Fnc’ button to go back to the
main menu level. The set point setting fold-
er is also closed when the time-out elapses.

FUNCTIONS

DEFROST CONTROL

The defrost cycle can be activated manual-
ly using the keyboard or automatically at
set intervals.

Defrost mode

The compressor remains off for the dura-
tion of defrosting. Defrosting terminates
only when the time out set with parameter

dE 

(defrost time out) expires.

Manual defrosting

Press the “UP” button to activate the defrost
cycle manually. 
If parameter 

Od 

is set to a value that is not

0 the cycle does not start, the request is
ignored and the display will flash three
times to indicate that defrosting is not pos-
sible.

Automatic defrosting

The defrost cycle is programmed to start at
set intervals determined by the value of
parameter dt. If parameter dt is set at
0 the defrost cycle cannot be activated. If
dt is higher than 0 then the time interval 
between defrosting can be counted

Compressor

•ON when

compressor is

on

•blinking for

delay, protec-

tion or enabling

blocked

Defrosting

•ON when

defrosting is in

progress;

•blinking when

activated

Alarm 

•ON for active

alarm;

•blinking when

a silenced

alarm is still

present

ID 400

controller for refrigeration units

cod. 9IS43086-1

rel. 08/09

EN

Scrolls through the menu items UP button
Increases value
of displayed parameters
Enabling of manual defrost 

DOWN button

Scrolls through the menu items
Decreases value of
display parameters.

fnc button

ESC function (quit one level 
of the current menu)

Set button

Press once to access
Set Point setting.
Press for at least 5 seconds to
access the programming menu
parameters
Confirms command and set 
values.

fnc

set

ID 400

LEDs

The ID400 is a microprocessor-based digital device used for the control of refrigeration
units. It is particularly suitable for applications on “static” units at low or normal temper-
ature. 
It has a relay output that controls the compressor and an NTC probe input (or PTC accord-
ing to availability) that controls cell temperature. Defrosting is effected by simply shutting
down the compressor. A series of alphanumeric parameters is used to configure the instru-
ment according to the application. The ID 400 is supplied in the ELIWELL standard 32x74
format

.

GENERAL DESCRIPTION

Par 1

Par n

PA1

0

set PA1 value

change

par value

scroll 

parameters

press for 5 sec

quit for time-out, fnc pressed 

or incorrect password

press and release

set point

set point

value

PROGRAMMING MENU

BUTTONS

Содержание ID 400

Страница 1: ...oes not start the request is ignored and the display will flash three times to indicate that defrosting is not pos sible Automatic defrosting The defrost cycle is programmed to start at set intervals...

Страница 2: ...agnetic compatibili ty EMC of the instrument special care must be used when wiring The power supply probe cables should be kept sepa rate from the power cables TECHNICAL DATA Front protection IP65 Cas...

Страница 3: ...dards for its construction as an automatic electronic control device to be independently mounted for its automatic operating features as a 1 B type operated control type device as a Class A device in...

Страница 4: ...te la pressione del tasto UP Nel caso in cui il parametro Od sia impostato diverso da 0 il ciclo non parte la richiesta viene scartata ed il display lam egger per tre volte indicando che lo sbrinament...

Страница 5: ...to dallo strumento Le sonde non sono caratteriz zate da alcuna polarit di inserzione e pos sono essere allungate utilizzando del nor male cavo bipolare si fa presente che l al lungamento delle sonde g...

Страница 6: ...monizzate europee di riferimento Esso classificato secondo la costruzione come dispositivo di comando automatico elettronico da incorporare a montaggio indipendente secondo le caratteristiche del funz...

Страница 7: ...metro Od est programado en un valor diferente de 0 el ciclo no arranca la peti ci n es ignorada y el display parpadea tres veces indicando que el descarche no es posible Descarche autom tico El arranq...

Страница 8: ...sondas no se caracterizan por ninguna polaridad de conexi n y pue den prolongarse utilizando un cable bipo lar normal t ngase en cuenta que la pro longaci n de las sondas afecta al compor tamiento del...

Страница 9: ...su seguridad seg n las normas armonizadas europeas de referencia El dispositivo est clasificado seg n su construcci n como dispositivo de mando autom tico electr nico para incorporar con montaje inde...

Страница 10: ...tauzyklus erfolgt mit Druck auf die Taste UP Ist der Parameter Od auf einen von 0 verschiedenen Wert eingestellt startet der Zyklus nicht die Anforderung wird bergangen und der Display blinkt dreimal...

Страница 11: ...nnung des Instruments berein stimmt Die F hler weisen keine besondere Einsetzpolung auf und k nnen mit normalem zweiadrigem Kabel verl ngert werden es sei darauf hingewiesen dass die Verl ngerung der...

Страница 12: ...evanten Aspekte auf der Grundlage der anwendbaren europ ischen Normen gepr ft Klassifizierung Konstruktionstechnisch als elektronische Automatiksteuerung zur Systemeinbindung mit unabh ngigem Einbau G...

Страница 13: ...givrage manuel L activation manuelle du cycle de d givrage a lieu en appuyant sur la touche UP Si la valeur du param tre Od est diff rente de 0 le cycle ne d marre pas la demande est reje t e et l af...

Страница 14: ...ation est conforme celui qui est exig par l instru ment Les sondes ne sont caract ris es par aucune polarit de prise et elles peuvent tre allong es en utilisant un c ble bipolaire normal ne pas oublie...

Страница 15: ...v rifi du point de vue de la s curit sur la base des normes europ ennes harmonis es en vigueur Il est classifi Selon la construction comme un dispositif de commande automatique lectronique incorporer...

Отзывы: