Elitech ECS-2180neo Скачать руководство пользователя страница 1

General warning 

Please read before using this manual 

 

This manual should be kept near the device as a quick 
reference 

 

This device should not be used for purposes different than 
described in manual 

 

Check application before proceeding 

Safety precautions 

 

Must be installed by a suitably qualified person 

 

Check the supply voltage is correct before connecting the 
device 

 

Do not expose the device to water or moisture, use the device 
within operating limits 

 

Disconnect all electrical connections before any kind of 
maintenance 

 

In case of failure or faulty operation please return to supplier           
with a detailed report of problem 

 

Show precaution in checking the current ratings of any device 
connected to relays 

 

Ensure probe cables are separate from power supply to avoid 
interference 

 

In industrial applications consider the use of mains filters in 
parallel with inductive loads 

General description 

ECS-2180 neo is a microprocessor based controller suitable for medium or 
low temperature refrigeration control. It has 3 relay outputs to control 
compressor fan and defrost, which can be electric or hot gas. Two NTC 
temperature probes are supplied for thermostatic control and for 
evaporator defrost control 

Functions 

Compressor  

The regulation is performed according to the temperature measured by 
the indoor probe (terminals 1&2). As temperature increases at reaches set 
point + differential and the compressor is started. As temperature 
decreases and reaches set point the compressor swill switch off. Visual 
indication on the display shows when compressor relay is engaged. This 
indicator flashes during a delay, such as avoiding short cycling 

Defrost 

The defrost mode can be selected for: electric heater or hot gas. For 
medium temp application an “off cycle” defrost can be utilised where 
defrost will occur when compressor is off 

Defrost is interval timed and this is adjustable by user. Defrost probe will 
end the period of defrosting or by interval period Defrost has visual 
indication on display 

Fan control (Evaporator indoor)  

The fan control is configurable to run only with compressor or to run 
continuously. Adjustable drip time is a feature designed to allow ice/water 
extra time to be removed from evaporator. Fan motor has high temp stop 
point as a safety feature preventing circulation of warm air 

 

 

SET: Press for 3 seconds to change set point, display shows St 

Press                     to increase set point 

Press                             to lower set point 

LED Display  

 

 

How to change parameters (Administrator menu) 

Press Set for 3 sceonds: 

Press  

Press Set and enter administrator password 55 by using  

Press                to increase 

Press                  to lower 

Once 55 is reached, push set and then  

Now push                       to go through administrator level 

Differential is changed by pushing set point on C1 use                 and  

               To increase or decrease differential 

Buzzer mute Press any key to silence alarm buzzer 

Other common parameters, can be accessed by pushing set button with 
following codes: 

D4 Defrost interval set range 0-90 hours. Time between defrosts 

D6  = defrost period set range 1-90 minutes. Length of defrost but this can 
be over ridden by defrost probe indicating that frost is clear 

A6 = Maximum temperature alarm range AL1-70 °C. High Temp alarm 

A5 = Minimum temperature alarm range -40 °C– AU1. Low Temp alarm 

Digital controller with defrost and fans 
management 

ECS-2180neo 