ELIS PLZEŇ a. s.
Project design, installation and service manual
Page 38 of 72
Electromagnetic flowmeter FLONET FH30xx
ELIS PLZE
Ň a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, phone.: +420 377 517 711, fax: +420 377 517 722
Es 90678K
6.4 Check on the meter operation conditions
Prior to filling the piping and the installed meter sensor with the fluid to be measured, make sure that
the fluid parameters (temperature and pressure) are within the limits specified on the meter plate, and
that any risk to life or health of personnel is excluded.
7 OPERATION
7.1 Meter energising
7.1.1 Display status
Upon turning the power on, all meter modules will undergo the initiation procedure. Following the display
test, the basic screen format with the following data will be shown:
•
Current volume flow rate
(if an error is detected, an error code is displayed next to the current flow)
•
Aggregate fluid volume passed through the meter sensor in the positive direction;
•
Aggregate fluid volume passed through the meter sensor in the negative direction.
The bar chart at the top of the display shows the current flow rate related to the specified maximum flow
rate.
Basic screen format
7.2 Front panel and control buttons
7.2.1 Display
The meter is provided with a colour OLED display of 128 x 64 pixels where all the measured quantities,
flowmeter parameters and important user information can be visualised. The display control is facilitated
by means of four optical buttons (optical reflex sensors).
7.2.2 Control button functions
Button locations with respect to the display
▲
►
■■■■■■■■■■■■■■■■■■■
1,025
m3/h
45,34
- 25,1
m
3
⃝
⃝
⃝
⃝
ESC
ENTER
3
2
1
4
1