Elinz BCSMART20 Скачать руководство пользователя страница 6

www.elinz.com.au / [email protected] / 1300 881 773 

Disconnecting 
Disconnect the appliance from the main supply. 
Remove the "-" pole clamp (black) from the "-" pole of the battery 
Remove the "+" pole clamp (red) from the "+" pole of the battery. 
 
Specifications: 

Charging type 

8-Stage Automatic 

Input voltage 

220-240V AC/50Hz 

Input power 

350W 

Output voltage 

12V DC and 24V DC 

Max output current 

Max 20A for 12V and Max 10A for 24V 

Minimum Start voltage 

4.2V 

Back Drain 

0mA 

Current fuse rating 

UL 250V/10A(PCBA) 

Efficiency 

85% 

Thermal Protect 

≥80

±5

), the charging currents drops to 2A, and 

≤70

±5

℃ 

recover normal currents 

Battery types 

Lead-Acid, Wet, MF, AGM Calcium, Gel 

Cooling fan 

Automatic temperature controlled 

Ambient temperature 

-20

 to +40

 

Over voltage protection  Please see details below 
Battery range 

12V 50-400Ah, 24V 25-200Ah 

DC charge cable Length 

DC cable to Anderson connector 1.5M / Clamp cable 
with Anderson connector 0.3M 

 

 Normal (12V Mode) - When the battery voltage more than 

14.3V±0.3V, the charger stops working 

 Low temperature (12V Mode) - When the battery voltage more 

than 14.7V±0.3V, the charger stops working 

 Normal (24V Mode) - When the battery voltage more than 

28.6V±0.3V, the charger stops working 

 Low temperature (24V Mode) - When the battery voltage more 

than 29.4V±0.3V, the charger stops working 

 
 
 

Содержание BCSMART20

Страница 1: ... to the health Avoid any contact with caustic battery acid immediately thoroughly flush skin and any objects which have come into contact with acid If eyes have come into contact with battery acid flush eyes with running water at least 5 minutes Contact your physician Use safely googles and acid proof safety gloves Protective clothing e g with an apron Never tip the battery as acid may leak Always...

Страница 2: ...treme heating Immediately stop using the device if you notice smoke or an unusual odor Do not use the device in rooms where explosive or flammable substances are stored e g petrol or solvents Risk of Electrical Shock Charges may interfere with the operation of active electronic implants e g pacemakers Avoid pouring or dripping water or other liquids over it If water penetrates electrical devices t...

Страница 3: ...y poles through conductive objects e g tools Never use the cable to carry or pull the device Risk of Injury Never attempt to charge non rechargeable damaged or frozen batteries Do not use this device to charge dry cell batteries These could burst resulting in personal injury and property damage Please read and follow the operating manual and all safety instructions for the batteries to be charged ...

Страница 4: ...ety Functions The charger features the following safety features to prevent damage to the charger and the battery or the vehicle Short circuit protection Reversed polarity protection Overheating Protection Excess current Overcharge protection LCD Display ...

Страница 5: ...red of the charger to the pole of the battery Connect the pole clamp black of the charger to the pole of the battery Connect the main cable with AC 230V VDE plug of the charger to the main socket Before start charging please press the Button to select with mode you want Then press the Button The charger to start to work If you want to stop charging please press the Button The battery voltage displ...

Страница 6: ...currents drops to 2A and 70 5 recover normal currents Battery types Lead Acid Wet MF AGM Calcium Gel Cooling fan Automatic temperature controlled Ambient temperature 20 to 40 Over voltage protection Please see details below Battery range 12V 50 400Ah 24V 25 200Ah DC charge cable Length DC cable to Anderson connector 1 5M Clamp cable with Anderson connector 0 3M Normal 12V Mode When the battery vol...

Страница 7: ...and health to make sure battery connections are good battery is in a stable condition Stage 3 Soft Start Starts the charging process gently to ensure an even flow across each cell before increase the charging rate Stage 4 Bulk Charge Allows the full voltage current output of the charger required by the battery depending on the chemistry mode selected Stage 5 Absorption Automatically reduces the cu...

Страница 8: ... should be initiated If the battery voltage falls below its target threshold the charger will restart the Maintenance cycle until voltage reaches its optimal state and then discontinues the charge cycle Stage 8 Silent Night Mode The Silent Night Mode is used to provide quiet operation by reducing the charge current to 2A and disabling the internal cooling fan For any inquires issue or comments con...

Отзывы: