Elgo IMAX Series Скачать руководство пользователя страница 1

 

 

 
 

 

Operating Manual 

SERIES 

IMAX 

Magnetic, Self-Referencing Pseudo-Absolute Linear Encoder 

 

 

 

Pseudo-absolute measurement by self-referencing 

 

Resolution 1mm and repeat accuracy ±1 mm  

 

Suitable for storage and conveyor technology  

 

Long measuring distances up to 1048 m possible 

 

CANopen standard (DS406 encoder profile) 

or SSI (binary or Gray) interface 

 

Robust housing for use in harsh environments 

 

Wear-free and contactless measuring principle 

 

Insensitive against dust, dirt and water  

799000870 / Rev. 1 / 2019-05-09 

Translation of the original operating manual 

Содержание IMAX Series

Страница 1: ...mm Suitable for storage and conveyor technology Long measuring distances up to 1048 m possible CANopen standard DS406 encoder profile or SSI binary or Gray interface Robust housing for use in harsh e...

Страница 2: ...z Str 1 D 78239 Rielasingen Worblingen Technical Support 49 0 7731 9339 0 49 0 7731 2 88 03 info elgo de Document No 799000870 Document Name IMAX 00 MA E_19 19 Document Revision Rev 1 Issue Date 2019...

Страница 3: ...7 5 Product Features 8 5 1 Functional Principle 8 5 2 Available Output Interfaces 8 6 Technical Data 9 6 1 Identification 9 6 2 Dimensions IMAX Sensor 9 6 3 Technical Data Sensor 10 6 4 Technical Data...

Страница 4: ...0 16 Figure 6 Magnetic tape construction BK80 16 Figure 7 Magnetic tape construction BK100 16 Figure 8 Sensor alignment to the magnetic tape 17 Figure 9 Mounting tolerances of the sensor 18 Figure 10...

Страница 5: ...r to avoid accidents damage and injuries Warning notes DANGER This symbol in connection with the signal word Danger indicates an immediate danger for the life and health of persons Failure to heed the...

Страница 6: ...evice if you have understood the operating manual The operating company is obliged to take appropriate safety measure The initial operation may only be performed by qualified and trained staff Selecti...

Страница 7: ...port Unpacking and Loading CAUTION Transport the package box palette etc professionally Do not throw hit or fold it 4 9 Handling of Packaging Material Notes for proper disposal 4 4 4 10 Inspection of...

Страница 8: ...request Measuring length up to 1048 resp 262 m 5 1 Functional Principle The IMAX sensor is guided over a magnetic tape which is written with an absolute track Due to automatic refer encing the curren...

Страница 9: ...ated on the housing of the device and indicates the exact type designation order reference 10 with the corresponding part number Furthermore the type label contains a unique traceable device number Wh...

Страница 10: ...0 80 10 1 R 15 adhesive mounting see section 7 2 4 AB20 80 10 1 R D 15 BK80 rail mounting see option 7 3 1 AB20 80 20 1 R D 15 BK100 rail mounting see option 7 3 2 Available magnetic tape lengths see...

Страница 11: ...ape with back iron without adhesive tape 1 35 mm 0 11 with back iron adhesive tape without protective foil 1 55 mm 0 13 with back iron adhesive tape protective foil 1 63 mm 0 14 Height of the cover ta...

Страница 12: ...not be in stalled close to sources of strong inductive or capacitive interference or strong electrostatic fields CAUTION The electrical connections must be made by suitably qualified personnel in acco...

Страница 13: ...n the standard case the magnetic tape is delivered as described below It is installed by gluing onto the respective mounting surface The magnetic tape consists of 2 pre assembled components see figure...

Страница 14: ...ur faces than 10 C because in this case the adhesive becomes too hard and perhaps a sufficient immediate adhesion is hardly to achieve After proper sticking the stability of the connection is ensured...

Страница 15: ...1 Resistance against Chemical Influence Show no or little effect in constant contact after 2 5 years formic acid glycerol 93 C linseed oil soy beans oil cotton seed oil N hexane lactic acid formaldeh...

Страница 16: ...e is not supplied with this variant Figure 6 Magnetic tape construction BK80 The exact ordering codes for the magnetic tapes can be found in section 10 1 Accessories 7 3 2 BK100 As shown in the follow...

Страница 17: ...indicated by arrows on the upper side of the magnetic tape 7 4 1 Sensor Alignment to the Magnetic Tape Figure 8 Sensor alignment to the magnetic tape The cable outlet of the sensor points towards the...

Страница 18: ...x 1 8 mm Lateral angle the maximum permissible reading distance must not be exceeded at any position Pitch angle the maximum permissible reading distance must not be exceeded at any position Lateral o...

Страница 19: ...h the IMAX an NMT command has to be sent first The following identifiers are given CAN Identifier 6 Byte telegram 181 16 Identifier First 4 bytes Position resolution 1 mm Bit rate 125 KB s Next 2 byte...

Страница 20: ...rmat of the SSI interface depends on the respective order designation in the type code 10 SSB0 binary code SSG0 Gray code 8 2 1 Connections SSI Interface Table 4 Connections SSI open cable ends Connec...

Страница 21: ...contactor coils of AC contactors e g 0 1 F 100 2 Installation of recovery diodes via DC inductors 3 Installation of RC circuits via the different motor phases in the terminal box of the motor 4 Do no...

Страница 22: ...on 00 standard version 01 first special version etc Interface SSB0 SSI interface 25 bit binary code max 262 m SSG0 SSI interface 25 bit Gray code max 262 m CAO0 CANopen interface DS406 encoder profile...

Страница 23: ...on 17 bit coded magnetic tape for IMAX with CAN open interface max coding length max measuring length 1048 m The maximum ordering length as roll material is 600 m Higher lengths are available on reque...

Страница 24: ...24 Notes...

Страница 25: ...25 Notes...

Страница 26: ...26 Notes...

Страница 27: ...0 Identification 9 Installation 12 Installation of the Magnetic Tape 13 Installation of the Sensor 17 Magnetic Tape Options BK80 BK100 16 Magnetic tape structure 11 Maintenance 21 Mounting Tolerances...

Страница 28: ...e IMAX 00 MA E_19 19 Subject to change 2019 ELGO Electronic GmbH Co KG ELGO Electronic GmbH Co KG Measuring Positioning Control Carl Benz Str 1 D 78239 Rielasingen Fon 49 0 7731 9339 0 Fax 49 0 7731 2...

Отзывы: