background image

 
 

 

 

 

Installation and First Start-Up 

- 12 - 

5

 

Installation and First Start-Up 

 

 

CAUTION 

Please read the operating manual carefully before using the device! Strictly observe the Installation instructions!  

In case of damage caused by failure to observe this operating manual, the warranty expires. 

ELGO is not liable for any secondary damage and for damage to persons, property or assets. 

The operator is obliged to take appropriate safety measures.  

The first start-up may only be performed by qualified staff that has been trained and authorized by the operator.

 

5.1

 

Operating Area 

 

WARNING! 

Do not use the device in explosive or corrosive environments! 

The device must not be installed close to sources of strong inductive or capacitive interference or strong electrostatic 

fields! 

 

 

 

NOTE: External Magnetic Fields 

The magnetic tape must not be influenced by external magnetic fields! The PMIX cylinder equipped with magnetic 

tape must not come into direct contact with other magnetic fields (e.g. permanent magnets, magnetic clamps, elec-

tromagnets, magnetic stands)! This may cause irreparable damage, which will compromise the measuring accuracy 

or even the functioning. 

 

 

 

 

 

 

 

 

 

CAUTION! 

The electrical connections must be made by suitably qualified personnel in accordance with local regulations. 

The device may be designed for switchboard mounting. During work on the switchboard, all components must be de-

energized if there is a danger of touching the energized parts!  

(protection against contacts) 

Wiring works may only be performed in the de-energized state! 

Thin cable strands have to be equipped with end sleeves! 

Before switching on the device, connections and plug connectors have to be checked! 

The device must be mounted in a way that it is protected against harmful environmental influences such as splashing 

water, solvents, vibration, shock and severe pollution and the operating temperature must not be exceeded. 

 
 

 

Содержание PMIX Series

Страница 1: ...ation with a battery powered ELGO display units of the series IZ Available resolutions 0 1 0 025 0 01 or 0 001mm depending on selected measuring system LMIX EMIX EMIX23 or IZ display unit Measuring le...

Страница 2: ...z Str 1 D 78239 Rielasingen Worblingen Technical Support 49 0 7731 9339 0 49 0 7731 2 88 03 info elgo de Document No 799000215 Document Name PMIX 000 MA E_20 19 Document Revision Rev 0 Issue Date 2019...

Страница 3: ...1 General 7 3 2 Functional Principle 7 3 3 Typical Applications 7 3 4 Measuring Systems and Resolutions 8 3 5 Power Supply Voltages and Output Levels 8 3 6 Pulse diagram 8 4 Technical Data 9 4 1 Iden...

Страница 4: ...r to avoid accidents damage and injuries Warning notes DANGER This symbol in connection with the signal word Danger indicates an immediate danger for the life and health of persons Failure to heed the...

Страница 5: ...ure The initial operation may only be performed by qualified and trained staff Selection and installation of the devices as well as their embedding into the controlling system require qualified knowle...

Страница 6: ...not throw hit or fold it 2 9 Handling of Packaging Material Notes for proper disposal 2 4 2 10 Inspection of Transport Check the delivery immediately after the receipt for completeness and transport...

Страница 7: ...200 400 600 mm The sensor is optimally guided at linear movements Thus the system can immediately be installed and connected 3 2 Functional Principle Integrated in the sensor head are the magneto resi...

Страница 8: ...er Supply Voltages and Output Levels For the LMIX and EMIX based versions the following combinations are available 1 Order suffix 00 10 30 VDC power supply output levels 10 30 V HTL 2 Order suffix 01...

Страница 9: ...ntains a unique traceable device number When corresponding with ELGO please always indicate this data 4 2 Dimensions Sensor Note The swivel head SAKB5F shown in the drawing above is an accessorial par...

Страница 10: ...150 mA max 50 m 11 5 VDC 5 Residual ripple 50 mV 5 V TTL Line Driver max 200 mA max 10 m 99 The sensor is already supplied by the battery power of the IZ position indicator Output current max 20 mA pr...

Страница 11: ...ermal length expansion L m L m x 1 K x K L tape length in meters relative temperature change Influence of external magnets External magnetic fields must not exceed 64 mT 640 Oe 52 kA m on the surface...

Страница 12: ...ernal magnetic fields The PMIX cylinder equipped with magnetic tape must not come into direct contact with other magnetic fields e g permanent magnets magnetic clamps elec tromagnets magnetic stands T...

Страница 13: ...0 30 VDC in Green Channel A Yellow Channel B Black Channel Z Violet Channel A Orange Channel B Grey Channel Z Screen Shield PE 6 2 Pin assignment with 9 pin D SUB Option D1 Table 6 Pin Assignment Opti...

Страница 14: ...es occur in spite of all the items stated above being observed please proceed as follows 1 Installation of RC circuits via contactor coils of AC contactors e g 0 1 F 100 2 Installation of recovery dio...

Страница 15: ...Disturbances Maintenance Cleaning 15 7 3 Maintenance The device is maintenance free 7 4 Cleaning WARNING The device can only be cleaned with a damp cloth do not use aggressive cleanser...

Страница 16: ...edge triggering selectable by parameter menu Power supply output levels 00 10 30 VDC 10 30 V HTL 01 10 30 VDC 5 V TTL line driver 11 5 VDC 5 V TTL line driver 99 Battery powered for combinations with...

Страница 17: ...Type designation 17 Notes...

Страница 18: ...Type designation 18 Notes...

Страница 19: ...8 Operating area 12 Operational safety 4 Order reference 9 Packaging material 6 Pin assignment with 9 pin D SUB connector Option D1 13 Pin assignment with open cable ends standard 13 Power Supply Volt...

Страница 20: ...e PMIX 000 MA E_20 19 Subject to change 2019 ELGO Electronic GmbH Co KG ELGO Electronic GmbH Co KG Measuring Positioning Control Carl Benz Str 1 D 78239 Rielasingen Fon 49 0 7731 9339 0 Fax 49 0 7731...

Отзывы: