background image

 

 

 
 

 

Operating Manual 

SERIE

 EMAX-HI 

Magnetic Absolute Length Measuring System 

 

 

 

 

High resolution - 1µm 

 

For highly dynamic controls 

 

8 m measuring length

 

 

Automatic distance detection via LED

 

 

Available Interfaces: SSI, CANopen or RS422 

On request: BISS-C or CAN BASIC ELGO  

 

Optionally, incremental square wave signals (A, B)  

or 1 Vss sine-cosine for dynamic movement control 

799000710 / Rev. 4

 

/ 2018-03-22 

Translation of the original operating manual 

Содержание EMAX-HI Series

Страница 1: ...ontrols 8 m measuring length Automatic distance detection via LED Available Interfaces SSI CANopen or RS422 On request BISS C or CAN BASIC ELGO Optionally incremental square wave signals A B or 1 Vss...

Страница 2: ...Str 1 D 78239 Rielasingen Worblingen Technical Support 49 0 7731 9339 0 49 0 7731 2 13 11 info elgo de Document No 799000710 Document Name EMAX HI 00 MA E_12 18 Document Revision Rev 4 Issue Date 201...

Страница 3: ...nical Data 8 4 1 Identification 8 4 2 Dimensions Sensor 8 4 3 Technical Data Sensor 9 4 4 Technical Data Magnetic Tape 10 5 Installation and First Start Up 11 5 1 Operating Area 11 5 2 Description ins...

Страница 4: ...to avoid accidents damage and injuries Warning notes DANGER This symbol in connection with the signal word Danger indicates an immediate danger for the life and health of persons Failure to heed thes...

Страница 5: ...fore using the device Observe the installation instructions Only start up the device if you have understood the operating manual The operating company is obliged to take appropriate safety measure The...

Страница 6: ...sible Only the operator is liable for damages caused by non conventional use 2 8 Safety Instructions for Transport Unpacking and Loading CAUTION Transport the package box palette etc professionally Do...

Страница 7: ...t Typical applications are linear drives 3 1 Functional principle A Hall sensor and a magneto resistive impedance measuring bridge are guided over a two track magnetic tape with a fine interpolation t...

Страница 8: ...t type designation order reference see type designation with the corresponding part number Furthermore the type label contains a unique traceable device number When corresponding with ELGO always indi...

Страница 9: ...e 5 m standard cable length others upon request Weight approx 50 g without cable cable approx 60 g m accessories Electrical Data Supply voltage 10 30 VDC Residual ripple 10 30 VDC 10 Power input max 1...

Страница 10: ...g length in meters Material carrier tape Precision strip 1 4310 X10CrNi 18 8 EN 10088 3 Double faced adhesive tape 3M 9088 observe instructions others on request Dimensions without adhesive tape 10 mm...

Страница 11: ...e installed close to sources of strong inductive or capacitive interference or strong electrostatic fields CAUTION The electrical connections must be made by suitably qualified personnel in accordance...

Страница 12: ...teed Install the sensor with M3 screws see chapter Dimensions of sensor Table 1 Mounting Tolerances Tolerances Magnetic tape type AB20 10 10 2 R 11 Ride height 0 1 mm max 0 5 mm without cover band 0 0...

Страница 13: ...ce The magnetic tape consists of 2 pre assembled components see Figure 4 Components of the magnetic tape below A magnetized flexible plastic tape Pos 3 which is connected with a magnetically conductiv...

Страница 14: ...e is 4 5 kg cm2 Gluing temperature The optimal gluing temperature is between 18 C and 30 C Avoid colder sticking sur faces than 10 C because in this case the adhesive becomes too hard and perhaps a su...

Страница 15: ...cover tape under great pressure 8 Safeguard the ends of the cover tape against peeling off e g by using end caps 7 5 3 1 Resistance against Chemical Influence Table 2 Resistance against Chemical Influ...

Страница 16: ...ssignment CA0 with optional incremental signals Cable connector 12 pin M12 x 1 PIN Function Color DKA cable see Accessories 7 3 4 5 6 7 8 9 11 12 10 2 1 1 0 V GND white 2 10 30 VDC brown 3 CAN L green...

Страница 17: ...ce Option CA0 When ordering option CA0 the EMAX HI measuring system is equipped with a CAN interface according to CANopen standard DS406 The following identifiers are given CAN Identifier 4 Byte teleg...

Страница 18: ...programmed Baud rate 8 Data bits 1Stop bit without parity bit in the following format 02h STX xxh ABS data MSB xxh ABS data xxh ABS data LSB 03h ETX 00h 0Dh The measured absolute position is shown bi...

Страница 19: ...vailable as an option push pull output stage short circuit proof Figure 9 Incremental sine cosine signals Parameter Description min typ max unit Medium voltage at sin at cos 2 4 2 5 2 6 V Amplitude si...

Страница 20: ...3 screws Additional fixation for linear or radial application as well as for protection of magnetic tape ends FS 1000 FS Guide rail 1000 length in mm PNO1 SSI PROFIBUS converter DKA 00 RCF0 050 XXXX 1...

Страница 21: ...ghs on request Connection unit side SN Number 00 Standard version RCF0 M12 thread 12 pin cable connector female 0 Elgo standard pin assignment EE F G H Connection customer side XXXX open wires twisted...

Страница 22: ...s occur in spite of all the items stated above being observed please proceed as follows 1 Installation of RC circuits via contactor coils of AC contactors e g 0 1 F 100 2 Installation of recovery diod...

Страница 23: ...ventional maintenance Non conventional maintenance can lead to severe injuries and damage of property Therefore Maintenance works may only be completed by staff that has been authorized and trained by...

Страница 24: ...50000Bit s for CAN 500k 500000Bit s for CAN 1MHz 1000000Bit s for CAN X Device address 0 F Standard Setting Device address 0 Standard version always with 12 pin M12 plug XXXX Version V sealed Version...

Страница 25: ...cribed ordering code Type Designation Options that are not required are filled in with HMAX 000 00 001 SB0 AA BBB CCC DDD EEEE F GGGG H I JJJJ EMAX HI with SSI Binary interface 25Bit HMAX 000 00 001 S...

Страница 26: ...Type designation 26 Notes...

Страница 27: ...ne Signals Option SC10 19 Installation 11 Interfaces 17 Magnetic tape structure 10 Maintenance 22 23 Mounting Tolerance 12 Operating area 11 Operational safety 4 Order reference 8 Ordering Example 25...

Страница 28: ...EMAX HI 00 MA E_12 18 Subject to change 2018 ELGO Electronic GmbH Co KG ELGO Electronic GmbH Co KG Measuring Positioning Control Carl Benz Str 1 D 78239 Rielasingen Fon 49 0 7731 9339 0 Fax 49 0 7731...

Отзывы: