Mini position indicator 

 

with magnetic length measuring system

  

(ELGO sensor MS20.60 and magnetic tape MB20.50) 

 

 

With sign 

 

5 digits pulse factor 

 

Programmable decimal point 

 

Digital brightness control  

 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

SERIE Z20-SN105-024 

(Z20-005 with enable of parameter settings by hardware link)

 

 

 

Z20-105-E_41-04

.pdf 

                                                                                                 Doku-Art.-Nr.799000235

 

Содержание Z20-SN105-024

Страница 1: ...stem ELGO sensor MS20 60 and magnetic tape MB20 50 With sign 5 digits pulse factor Programmable decimal point Digital brightness control SERIE Z20 SN105 024 Z20 005 with enable of parameter settings b...

Страница 2: ...ic tape MB 20 50 5 2 Sensor MS 20 60 6 5 PARAMETER SETTING 7 Registers 7 Programming example 7 6 HINTS FOR INSTALLATION AND OPERATION 8 Hints for Operation in Electrical panels 8 Hints on mounting the...

Страница 3: ...10 sec Rate 2 at 10 HZ for 10 sec Rate 3 at 1000 HZ as long as pushbutton are depressed It is necessary shortly before the desired value is reached to release the button and reactivate so as to approa...

Страница 4: ...ent will operate satisfactorily with a measuring gap of 0 1 to 2 0 mm Protection Class The magnetic measuring system offers the greatest protection against hostile environments Sensor and tape are pro...

Страница 5: ...nical damages and is at the same time a magnetic short circuit This increases significantly the functional security under extreme magnetic influences A and B are already factory bonded C To keep the f...

Страница 6: ...ap between sensor and measuring tape must not be larger than 0 1 2 0 mm Sensor cable length signal processing Z20 005 is a combination of the indicator and the sensor The sensor wire is available in t...

Страница 7: ...3 07 Sign 0 active 1 inactive 08 Pulse factor 0 0001 9 9999 09 Datum value 0 0001 9 9999 14 Display brightness Set 0 9 0 9 dark 16 Enable of Par 09 0 Nr 09 disabled 2 Nr 09 enabled Programming example...

Страница 8: ...es and input signal cables Tie screen to zero terminal 1 at controller leave insulated at other end 6 Suppress all relays contractors solenoids brakes and other coils in cabinet and on machine Fit dio...

Страница 9: ...ose Also included is a double side adhesive strip Available in rolls from 0 5 to 25 m in length Length 0 5 to 25 m Repeat accuracy 0 01 mm Accuracy at 20 C in mm 0 025 0 02 x L L Length in m Temperatu...

Страница 10: ...8 Dimensions Cut out Side view External dimensions 66 mm 44 mm 48mm 62mm 57mm 77mm F RESET SET ELECTRIC ELGO 48mm 72mm 10...

Страница 11: ...ing level by hardware link Supply voltage 024 24 V DC AC 10 Encoder input 9 Magnetic sensor 0 01 mm resolution Special Features No options at the moment Accessories Magnetic tape MB 20 50 25 0 Increme...

Страница 12: ...keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistakes The guarantee period is one calendar year EC Dir...