background image

 

4

 

 

Operation 

 

These indicators may be fully controlled from four simple push buttons:-

 

 

 

 
Function select 

 

Must be pressed with another button to select required function.  
Pressed on its own, returns from selected function to operation, and stores edited value to 
RAM. 

 
 

Twin Datum 

 
 

When pressed on its own, adds the Datum Offset to the actual position. Press again to 
subtract. 

 

Certain machines, such as panel saws with turnover stops, require two datums with a fixed 
offset that can be readily toggled. 

 

 

Incremental / Absolute operation 

 

 

When pressed on its own, switches between absolute and incremental operation. 
 
In many applications dimensions are given on drawings, which are relative dimensions. Most 
position indicators display only the absolute position and it is necessary to calculate the new 
absolute position  
 
e.g.      1928.7 + 325.9 = 2254.6 
 
This is laborious and can lead to errors. 
 
This can be avoided by the use of this range of indicators. The operator can select 

 

= "Incremental". This sets the display to zero. Operator can now move 325.9 and re-

select 

 

 

 

= "Absolute" ( the display now reads 2254.6 ) 

F

 

F

Содержание 54 AG Series

Страница 1: ...Z54 Z56 Series Z54 56 000 E_41 99 doc Doku Art Nr 799000101 Programmable Position Indicators Series 54 For use with Encoders Series 56 For use with MX magnetic scale...

Страница 2: ...dit datum Offset 6 Edit Datum 1 bit 6 Edit Flexible Multiplier 6 Changing Display Value 7 Counter Configuration 7 Configuration Register 8 Direction of Count 9 Decimal Places 9 Inch Metric Switching 9...

Страница 3: ...xternal inputs The Range available is as follows Series 54 single axis indicator available in LED or LCD display formats Suitable for encoder feedback Series 56 single axis indicator available in LED...

Страница 4: ...s with a fixed offset that can be readily toggled Incremental Absolute operation When pressed on its own switches between absolute and incremental operation In many applications dimensions are given o...

Страница 5: ...fset It is only possible for the operator to edit the Datum and Datum Offset if the editing feature is unlocked in the configuration register XXX0X NB The Datum and Offset values incorporate any decim...

Страница 6: ...e is not possible when this feature is selected Press both buttons for three seconds any value may now be set in the normal way subtracts one bit press adds one bit press to the displayed value Edit F...

Страница 7: ...ment the digit between 0 and 9 stores the value to the internal RAM and returns the indicator to operating mode Counter Configuration F Press buttons for three seconds the Configuration mode is entere...

Страница 8: ...X X X X X Series 54 Encoder feedback only Series 56 Scale feedback only Display extinguish 0 No auto extinguish and no clamp extinguish 1 Total power off on with F button 2 Total power off after 5 min...

Страница 9: ...ction Press F to store value to RAM and return to Config Press all four buttons again for three seconds to return indicator to operating mode General Technical Information Indicators Maximum counting...

Страница 10: ...20 60 Maximum speed of travel 5m sec Cable length 3m standard up to 25m available Operating temperature 5 to 45 deg C Sealing IP66 Magnetic Tape MB20 50 xx x Resolution 0 1mm Operating temperature 5 t...

Страница 11: ...tion ST3 AC input Pin 1 L Pin 2 N Pin 3 E ST2 Encoder Pin 1 0 volts Pin 2 24 volts dc Pin 3 Channel A Pin 4 Channel B Pin 5 Screen ST3 Series 56 AG BU1 ST3 AC input Pin 1 L Pin 2 N Pin 3 E BU1 MX magn...

Страница 12: ...ns Outline Dimensions Side View 92mm 66mm 72 mm 96mm 62mm 68mm mm 107mm 76 95mm 90mm M6 60mm 30mm Panel Mounting Series 54 and 56 AG Enclosure Mounting Series 54 and 56 NG20 0 Power Supply 80mm 45mm D...

Страница 13: ...For 56 series indicators to operate on 110 230 v ac use the 024 version and order a separate NG20 0 power supply AG versions always include NG20 0 mounted inside the enclosure 600 For Version 230 or 1...

Страница 14: ...24 V DC 115 115VAC in 54 only 230 230VAC in 54 only Construction 000 standard 001 1 st special version etc Special Features EE External input AG Free standing Housing RS232 Serial port in 54 only M h...

Страница 15: ...ly strive for improving our products therefore we keep all rights reserved for any technical modifications without any notice ELGO Electric does not assume any liability for possible errors or mistake...

Отзывы: