7.18
Controller Manual
Troubleshooting
7.9
S.
NO
Failure symptoms
Possible causes
Remedies
1
No display in LCD
Screen & Backlight was
not glown
No input supply
Check incoming supply to compressor
Transformer failure
Please check the controller input voltage at connector
X01. Voltage should be 24V ± 15% VAC.
Controller failure.
Change the controller.
2
Keypad in Controller not
responding
Key not responding
Check any key stuck / Flat. If any change Controller
Key struck / Flat
Change the controller.
3 "Low voltage" message
in display.
Controller Input voltage less than
18VAC
Until will start functioninig, once input voltage recovered
to nominal or with in specification ( 415 V +10% - 15
%)
4
"Pr. probe failure"
message in display
Loose connection in connector
position (X02 - 7 & 8).
Check the loose connection at both end - Controller and
pressure sensor side.
Pressure sensor failure.
Change the Pressure sensor.
Controller failure
Check the voltage across (X02 - 8) with Gnd, voltage
should be b/w 0.4 to 2VDC. If it is different change the
controller.
5
"Tr. probe failure"
message in display
Loose connection in connector
position X02 - 9 & 10.
Check the loose connection at both end - Controller and
Temp sensor side.
Temperature sensor failure.
Change the Temperature sensor.
Controller failure
Check the voltage across X02 - 9 with Gnd, voltage
should be 3.3 VDC. If it is different change the
controller.
6
"Emergency stop"
"MMOL"
"Cooler OL"
message in display
Loose connection in connector
position (X02 - 1, 2 ,3 & 4).
Check the loose connection at controller end.
Switch got struck
Check either the external switches got sturck / Fault not
cleared
Controller Failure
Change the controller.
7 Motor not driving
Controller failure
Disconnect the X03 & X04 connector,
Check the relay working by switching on the start key
(X03 -1) with (X03- 2, 3 & 4) & (X04 -1) with (X04- 2).
Note: Ckeck in the continuity mode.
8
"Phase loss/ Reverse"
message in display
Loose connection in connector
position (X05 - 1, 2 & 3).
Check the loose connection at controller end.
Controller failure
Check for the X05 connection X05(1- R, 2-Y, 3 -B), Still
the same error change the controller
Содержание EN 30X-100
Страница 1: ......
Страница 2: ......
Страница 3: ...Product Manual EN Series Electric Powered Screw Air Compressor EN 37 100 208 230 460V 3Ph 60Hz...
Страница 8: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 59: ...Controller Manual Neuron XT Version 3 0 January 2018...
Страница 80: ...7 22 Controller Manual Menu Structure...
Страница 81: ...PARTS MANUAL EN SERIES ELECTRIC POWERED SCREW AIR COMPRESSOR EN 30X EN 37...
Страница 82: ...8 2 Parts Manual 8 0 Air inlet and control system Ref 015315272 X016550 21...
Страница 84: ...9 1 Parts Manual 9 0 Drive system Ref 015310622 X015310 EN 37 100 PSI...
Страница 86: ...10 1 Parts Manual 10 0 Discharge system Ref 015310612 X015300 EN 30 EN 37...
Страница 88: ...11 1 Parts Manual 11 0 Cooling system Ref 015310616 X015304 EN 37...
Страница 90: ...12 1 Parts Manual 12 0 Lubrication system Ref 015315274 X016552 EN 37...
Страница 92: ...13 1 Parts Manual 13 0 Base and canopy system Ref 015310618 X015306 EN 37...
Страница 96: ...12 3 Kit Details...
Страница 97: ...POWER CIRCUIT 8 3 1 0 6 2 2 2 9...
Страница 98: ...CONTROL CIRCUIT 6 2 1 8 0 3 2 2 9...
Страница 99: ...BOM 8 1 0 3 6 2 2 2 9...
Страница 100: ...PANEL LAYOUT 0 2 6 3 1 8 2 2 9...
Страница 101: ...POWER CIRCUIT 8 3 1 0 6 2 2 2 9...
Страница 102: ...CONTROL CIRCUIT 6 2 1 8 0 3 2 2 9...
Страница 103: ...BOM 8 1 0 3 6 2 2 2 9...
Страница 104: ...PANEL LAYOUT 0 2 6 3 1 8 2 2 9...
Страница 107: ......
Страница 108: ......