5.4
Installation and operation
these may erode the internal components and also
contaminate the oil and filters.
Do not allow hot air from additional equipment to blow
towards the compressor.
If you operate in high dust applications like rice mills,
cement, flour mills, etc., clean and replace the filters
more often.
Good practice is to have overhead lifting in the
compressor room to facilitate any major overhaul. If an
overhead hoist is not available, you should be able to
use a mobile crane or forklift truck in your compressor
room at a minimum.
5.1.5 Ventilation and exhausting hot air
Ensure adequate ventilation in the compressor
installation area. Your compressor has a ventilating air
requirement of 600 to 1200 cfm.
Guidelines to compressor ventilation setup:
Follow these guidelines when providing ventilation for the
compressor:
Provide openings close to the floor level on walls/
partitions close to the air suction side of the compressor
Provide exhaust openings close to the ceiling for hot air
exit.
Ensure the air velocity in the supply and exhaust ducts
does not exceed 13.1ft/s (4m/s).
Determine air velocity during commissioning using an
anemometer.
Do not connect cool air inlet ducts directly to the
compressor inlet side.
To eliminate transmission of vibrations, provide a soft
bellows connector between the duct and the
compressor.
Contact ELGi in case you need to provide a duct
connection or filter fitment on the compressor.
Do not direct forced flow of cool air towards the
compressor.
Locate the compressor such that hot air from other
machines is not directed towards it.
5.1.6 Electricals
Electricals 60Hz
You must provide a lockable main switch unit with pre-
connected slow-blow main fuses as per industrial safety
regulations. Power supply should be 208/230V 1 Ph 60Hz
with earth PE or 208-230V/460V 3 Ph 60Hz with earth PE.
The fuse and cable specifications for 208-230V, 60 Hz 1
Ph, 208-230V 60Hz 3ph and 460V 60Hz 3ph power
supplies appear in the table below.
You must also provide a switching fuse unit with pre-
connected slow-blow main fuses as per industrial safety
regulations. Power supply should be 208/30V 1 Ph with
earth PE or 208-230V/460V 3 Ph with earth PE.
The fuse and cable specifications for 208-230V, 60 Hz 3 Ph
and 460V 60Hz 3ph power supplies appear in the table
below.
Electricals 50Hz
You must provide a switching fuse unit with pre-connected
slow-blow main fuses as per industrial safety regulations.
The power supply should be 380V/400V/415V, 50Hz, 3
phase with (PE) earthing.
The fuse and cable specifications for 380V/400V/415V,
50Hz, 3 Ph power supplies appear in the table below.
You must provide a switching fuse unit with pre-connected
slow-blow main fuses as per industrial safety regulations.
The power supply should be 380V/400V/415V, 3 phase
with Neutral.
The fuse and cable specifications for 380V/400V or 415V,
50Hz, 3 Ph power supplies appear in the table below .
Ensure that only authorized electricians perform electrical
work. Study the electrical circuit diagram before starting
work.
NOTE
Suspended particulate matter should be less than 150 spm
to achieve the specified consumable life.
Guarantee is void if the compressor is operated above its
intended pressure.
Power supply
208-230 V 3Ph
460 V 3Ph
Motor Power kW/
hp
30/40
37/50
30/40
37/50
Nominal current
(A)
105
135
50
65
Cable material
Copper conductor only
Power supply cable
(AWG) (L=30ft)
3*1/50
3*
(2/0)/70
3*6/16
3*4/25
Upstream fuses (A)
(Type RK/CC/J)
160
200
80
100
Model
Recommended
pre-connected
fuse rating (A)
Incoming
copper cable
size (mm
2
)
Incoming
aluminium
cable size
(mm
2
)
30 kW
100
25 Sq.mm
35 Sq.mm
37 kW
125
35 Sq.mm
55 Sq.mm
4 5kW
150
50 Sq.mm
70 Sq.mm
NOTE
Supply power to the compressor through a fuse switch unit
of a suitable rating mounted on the compressor at a height
of 5mm.
Содержание EN 30X-100
Страница 1: ......
Страница 2: ......
Страница 3: ...Product Manual EN Series Electric Powered Screw Air Compressor EN 37 100 208 230 460V 3Ph 60Hz...
Страница 8: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 59: ...Controller Manual Neuron XT Version 3 0 January 2018...
Страница 80: ...7 22 Controller Manual Menu Structure...
Страница 81: ...PARTS MANUAL EN SERIES ELECTRIC POWERED SCREW AIR COMPRESSOR EN 30X EN 37...
Страница 82: ...8 2 Parts Manual 8 0 Air inlet and control system Ref 015315272 X016550 21...
Страница 84: ...9 1 Parts Manual 9 0 Drive system Ref 015310622 X015310 EN 37 100 PSI...
Страница 86: ...10 1 Parts Manual 10 0 Discharge system Ref 015310612 X015300 EN 30 EN 37...
Страница 88: ...11 1 Parts Manual 11 0 Cooling system Ref 015310616 X015304 EN 37...
Страница 90: ...12 1 Parts Manual 12 0 Lubrication system Ref 015315274 X016552 EN 37...
Страница 92: ...13 1 Parts Manual 13 0 Base and canopy system Ref 015310618 X015306 EN 37...
Страница 96: ...12 3 Kit Details...
Страница 97: ...POWER CIRCUIT 8 3 1 0 6 2 2 2 9...
Страница 98: ...CONTROL CIRCUIT 6 2 1 8 0 3 2 2 9...
Страница 99: ...BOM 8 1 0 3 6 2 2 2 9...
Страница 100: ...PANEL LAYOUT 0 2 6 3 1 8 2 2 9...
Страница 101: ...POWER CIRCUIT 8 3 1 0 6 2 2 2 9...
Страница 102: ...CONTROL CIRCUIT 6 2 1 8 0 3 2 2 9...
Страница 103: ...BOM 8 1 0 3 6 2 2 2 9...
Страница 104: ...PANEL LAYOUT 0 2 6 3 1 8 2 2 9...
Страница 107: ......
Страница 108: ......