32
5. SUPPLY SET
SUPPLY SET
INCLUDES
Gas hob
1 pcs.
Mounting kit
1 pcs.
Operating manual
1 pcs.
Kit for switching to liquefied gas
1 pcs.
Warranty card
1 pcs.
Packaging
1 pcs.
6. INSTRUCTIONS FOR INSTALLATION OF THE HOB.
ATTENTION!
DISCONNECT THE HOB FROM ELECTRIC NETWORK
BEFORE CHECKOUT, MAINTENANCE, ETC.
ATTENTION!
THE HOB MUST BE INSTALLED AND USED IN
ROOMS WITH CONSTANT VENTILATION
6.1.
This section is intended for skilled technicians and contains instructions for
installing and servicing the hob according to the current safety regulations.
6.2.
To ensure the normal operation of the hob, as well as compliance with safety
regulations, the following requirements must be met:
— Room must have ventilation system, sufficient for the removal of combustion
products.
— Fresh air must be in the room for proper combustion. The inflow of air must be at
least 2 m
3
/hour per kilowatt of installed equipment.
— Liquefied gas is heavier than air and therefore accumulates below. Rooms, in which
liquefied gas cylinders are installed, must be equipped with external ventilation so
that gas can flow through it in case of leakage.
— It is not possible to install and store cylinders with gas in premises below the floor
level (in basements and semi-basements).
— It is recommended to keep in the kitchen only the used cylinder and install it away
from sources of heat (ovens, fireplaces, stoves, etc.) that can heat the cylinder to
a temperature above 50 ºС.
6.3.
Gas hobs have an appropriate degree of protection against overheating of
type X, so they can be installed next to furniture, the height of which does not exceed
the height of the working surface.
6.4.
The tabletop, on which the hob is installed, must withstand a temperature of
100 °С.
6.5.
The wall behind the gas hob must be lined with heat-resistant material (ceramic
tile, etc.).
Содержание ASTRA
Страница 1: ...1 ...