INSTALLATION
SINUS K
INSTRUCTIONS
12/
191
3.
INSPECTION
UPON
RECEIPT
OF
THE
GOODS
Make sure the equipment is not damaged and it complies with the equipment you ordered by referring to the nameplate
located on the inverter front part. The inverter nameplate is described below. If the equipment is damaged, contact the
supplier or the insurance company concerned. If the equipment does not comply with the one you ordered, please contact
the supplier as soon as possible.
If the equipment is stored before being started, make sure that the ambient conditions do not exceed the ratings
(mentioned in chapter 7 “Installing the equipment”). The equipment guarantee covers any manufacturing
defect. The manufacturer has no responsibility for possible damages due to the inverter transportation or
unpacking. The manufacturer is not responsible for possible damages or faults caused by improper and
irrational uses; wrong installation; improper conditions of temperature, humidity, or the use of corrosive
substances. The manufacturer is not responsible for possible faults due to the inverter operation at values
exceeding the inverter ratings and is not responsible for consequential and accidental damages. The equipment
is covered by a 3-year guarantee starting from the date of delivery.
SINUS
K
0005
4
T
B
A2
X
2
1 2 3 4 5 6 7 8 9
1
Product line:
SINUS stand-alone inverter
SINUS BOX inverter contained inside a box
SINUS CABINET inverter contained inside a cabinet
2
"K" type of control with three types of software installed:
IFD = Space vector modulation for general-purpose applications (vectorial modulation PWM with V/f
pattern)
VTC = Vector Torque Control for high torque demanding applications (Sensorless vectorial control with
direct torque control)
LIFT = Space vector modulation with a special software for lift applications
(vectorial modulation PWM with V/f pattern - NOT COVERED IN THIS MANUAL)
3
Inverter Model
4
Supply voltage
2 = power supply 200÷240Vac; 280÷340Vdc.
4 = power supply 380÷500Vac; 530÷705Vdc.
5
Type of power supply
C=Direct current supply T = three-phase
D=12 Impulse Bridge S = single-phase (available by request)
6
Braking unit
X = no braking chopper (optional external braking chopper)
B = built-in braking chopper
7
Type of EMC filter:
I = no filter, EN50082-1, -2.
A1 = integrated filter, EN 61800-3 issue 2 FIRST ENVIRONMENT Category C2, EN55011 gr.1 cl. A for
industrial and domestic users, EN50081-2, EN50082-1, -2, EN61800-3-A11.
A2 = integrated filter, EN 61800-3 issue 2 SECOND ENVIRONMENT Category C3, EN55011 gr.2 cl. A for
industrial users, EN50082-1, -2, EN61800-3-A11.
B = integrated input filter (type A1) plus external, output toroid filter, EN 61800-3 issue 2 FIRST
ENVIRONMENT Category C1, EN55011 gr.1 cl. B for industrial and domestic users, EN50081-1,-2,
EN50082-1, -2, EN61800-3-A11.
8
Control panel
X = no control panel provided
K = control panel provided (back-lit, 16x2 characters LCD display).
9
Degree of protection
0 = IP00
2 = IP20
3 = IP24
4 = IP42
5 = IP54
Содержание SINUS K
Страница 49: ...SINUS K INSTALLATION INSTRUCTIONS 49 191 S65 T S R U V W S64 Figure 8 Installation Example of a SINUS K S64 S65...
Страница 157: ...SINUS K INSTALLATION INSTRUCTIONS 157 191 Figure 75 Mechanical features of an AC 3 phase inductance...
Страница 186: ...INSTALLATION SINUS K INSTRUCTIONS 186 191 15 DECLARATIONS OF CONFORMITY...
Страница 187: ...SINUS K INSTALLATION INSTRUCTIONS 187 191...
Страница 188: ...INSTALLATION SINUS K INSTRUCTIONS 188 191...
Страница 189: ...SINUS K INSTALLATION INSTRUCTIONS 189 191...
Страница 190: ...INSTALLATION SINUS K INSTRUCTIONS 190 191...
Страница 191: ...SINUS K INSTALLATION INSTRUCTIONS 191 191...