eletor Speed Control Series Скачать руководство пользователя страница 1

SPEED CONTROL - SERVOMOTOR

Instruction Manual

Microprocessor climate controller belonging to the SPEED CONTROL family. A reliable
device, easy to assemble and utilize with a software available in four build-in language
versions: Polish (default), English, German and Russian. Its programme allows the user
to intuitively set various parameters such as: the temperature, airing, heating, min/max
fan speed and the alarms. 

Parameters and features:

Ventilation 1

st

 stage

output current smooth regulation up to 5A

thermal overload protection

soft start

minimal fan speed calibration

Ventilation 2

nd

 stage, separated relay up to 3A (one to choose)

air heating, separated relay up to 3A (one to choose)

NO/NC alarm outputs

power outage signalling

min/max temperature threshold exceedance signalisation

one analog input  for the temperature measurement 

two 0-10V outputs 

power consumption of <3W

IP56 hermetic enclosure

230V AC 50 Hz power supply voltage 

Climate controller with output

current permissible up to 5A

ELETOR SC-SERVOMOTOR

2019.08.14

ELETOR

ELETOR, Zbiczno 43D, 87-305 Zbiczno, Poland, tel. 056 4939379

www.eletor.pl

   |   

email:[email protected]

Содержание Speed Control Series

Страница 1: ...urrent smooth regulation up to 5A thermal overload protection soft start minimal fan speed calibration Ventilation 2nd stage separated relay up to 3A one to choose air heating separated relay up to 3A...

Страница 2: ...be avoided the sensor should not be placed directly by the door or ventilation holes the sensor should not be placed in spots accessible for animals it is advised to arrange the wire connected to the...

Страница 3: ...should not be guided from the power supply the switching station Instead they ought to be connected to the connectors of the controller Connector labelled as FUNCTION relay separated output with max...

Страница 4: ...e settings on the device based on current weather conditions outside the building as well as and most importantly based on the observation of the behaviour of all animals The user should also monitor...

Страница 5: ...ing to the behaviour of animals in the breeding room and all the conditions that occur not only inside but also outside of the building it is possible to completely turn off the airing function to do...

Страница 6: ...sible variants of this setting Airing level 20 Airing level during the ventilation process Alarm minimum 12 0o C Alarm minimum indicates the minimal absolute temperature value signalling the alarm act...

Страница 7: ...troller to the fan or the inverter Inversion V1 No The activation of this setting triggers the reversion of V1 output characteristics The voltage will drop as the ventilation level in the min max rang...

Страница 8: ...Manual before installation and further usage The user should not interfere with the device construction or perform any repairs This applies in particular to modifying various elements or components M...

Страница 9: ...tion 0 1o C Temperature sensor damage detection YES Maximum number of analog sensors 1 Temperature measurement accuracy analog input 1o C Dependence of wire resistance on the measurement analog input...

Отзывы: