6. EC Declaration of conformity

We reserve the right to make technical changes

20

elero GmbH

Antriebstechnik

Linsenhofer Straße 65 
D-72660 Beuren

 Fon: +49 7025 13-01 
Fax: +49 7025 13-212

[email protected]
www.elero.com

EC DECLARATION OF CONFORMITY 

We hereby declare that the following mentioned product/s meet/s the Machinery Directive 2006/42/EC

.

Product designation: 

Chain wheel rolling door drive

  DKM (-ZE)  170, 250, 350, 400, 500, 750 with NHK / SHK 

  WKM (-ZE) 170, 200 with NHK / SHK 

Description: 

Shaft mounted drive for operation of rolling doors with elero control units 

The conformity of the above mentioned products with the relevant health and safety requirements is taken into 
account by the following directives and standards: 

 EMC 

Directive 

2004/108/EC 

 

DIN EN 61000-3-2 (VDE 0838-2):2006 

 

DIN EN 61000-3-3 (VDE 0838-3):1995 

 

DIN EN 55014-1 (VDE 0875-14-1):2006 

 

DIN EN 55014-2 (VDE 0875-14-2):1997 

  Low Voltage Directive 2006/95/EC 

 

DIN EN 60335-1 (VDE 0700-1):2007 

 

DIN EN 60335-1/A13 (VDE 0700-1/A13):2009 

 

DIN EN 60335-2-103 (VDE 0700 Teil 103):2003 

 

DIN EN 62233 (VDE 0700-366):2008 

 

DIN EN 62233 (VDE 0700-366 Ber. 1):2009 

 RoHS 

Directive 

2006/95/EC 

  DIN EN 12453:2001 

  DIN EN 12604:2000 

Beuren, 14.10.2011 

 

 

 

 

 

 

 

Ulrich Seeker 
-CE Manager-, -Representative documentation -

Содержание DFE 100

Страница 1: ...mit switch setting 10 Digital limit switch 11 Mounting of shaft mounted drives 12 4 Manual operation Manual operations 13 5 Service 14 6 Manufacturer s declaration 16 For the safety of persons it is i...

Страница 2: ...such cases Observance of the assembly instructions is the prerequisite for disturbance free operation and fulfilment of any claims related to defects Therefore first read the assembly instructions bef...

Страница 3: ...nes 2004 108 EU are observed The technical data and the information on connection conditions can be found on the type plate and in this documentation and must be strictly adhered to WARNING Observe th...

Страница 4: ...e it from the mains supply 1 10 Safety instructions for the electrical connection Notes for the inspector The rolling door drives are maintenance free alternating current three phase current drives wi...

Страница 5: ...rt is in good mechanical condition its weight is balanced and it can be opened and closed easily Always use a suitable aid for a drive that weighs more than 20 kg A hole is available for this in the g...

Страница 6: ...range 19 revs Hollow shaft inside mm 30 40 Key width mm 8 12 Integrated safety brake Type F 40 F 80 Stop torque Nm 884 2302 Deceleration g 1 5 2 0 T V S D certificate no TorFV 5 061 5 062 VDE checked...

Страница 7: ...50 WFM WFE 170 NHK SHK 40 12 120 85 170 DFM 500 590 DFM 750 615 43 3 l10 2 4x 8 5 125 300 20 Y 5 l13 x 30 l13 x 30 40 12 120 85 170 DFM 500 590 DFM 750 615 43 3 l10 2 4x 8 5 125 300 20 DFM 500 810 DF...

Страница 8: ...3899 3787 3789 3791 3693 3695 3697 3434 3437 3441 Profile thickness of curtain 30 mm 3 4779 2613 1583 4328 4329 3899 3957 3959 3960 3825 3827 3829 3475 3478 3481 Door height m 5 4091 2613 1583 3827 3...

Страница 9: ...he strand with the star terminals in the clamps of the terminal or card cage when making a 3 400 V Y connection The on site control units that are from another manufacturer must be designed for elero...

Страница 10: ...of the micro switch and fasten the fixing screw Use the fine adjustment screw black to turn it for another max 35 until the micro switch switches 3 Approach the door to the desired lower end position...

Страница 11: ...rface RS 485 6 pin AMP plug no function 3 12 Left hand roller The drive is set up and wired in the factory as a right hand roller see sketch If the drive is to be set up as a left hand roller see sket...

Страница 12: ...ust be welding material meeting the standard DIN 17100 X Height difference Drive bracket counterpart bracket 3 Install the drive and the pedestal bearing To connect drive and bracket use hexagonal bol...

Страница 13: ...peration may only be made from a safe position Do not move the door beyond its end positions during manual operation Install the supplied wall chain holder so that the reel chain is not hanging in the...

Страница 14: ...o voltage Check the mains connection Mains ok Drive does not run Operating limit switch overrun Move manually inside the safety limit switch boundaries Check the phase sequence Safety limit switch ok...

Страница 15: ...elero GmbH EN 15...

Страница 16: ...f rolling doors with elero control units The conformity of the above mentioned products with the relevant health and safety requirements is taken into account by the following directives and standards...

Отзывы: