background image

-10-

RESISTANCE/DIODE TEST

1) Measure a resistor of about half of the full scale value of each resistance range. Compare the kit meter

readings to those from a meter of known accuracy.

2) Measure the voltage drop of a good silicon diode. You should read about 700mV. Power diodes and the

base to emitter junction of power transistors may read less.

If any of these tests fail:
a) Check the values and the soldering of resistors R1 - R6, and R18.
b) Check that transistor Q1 is mounted as shown in the assembly instructions.

h

FE

1) Set the range switch to h

FE

and insert a small transistor into the appropriate NPN or PNP holes in the

transistor socket.

2) Read the h

FE

of the transistor. The h

FE

of transistors varies over a wide range, but you will probably get a

reading between 100 and 300.

If this check fails:
a) Check that the transistor socket is aligned according to Figure 4-4.
b) Check the value and soldering of resistors R9, R21, and R22

AC VOLTS TEST

To test the ACV ranges, we will need a source of AC voltage. The AC power line is the most convenient.

CAUTION: Be very careful when working with 120VAC. Be sure that the range switch is in the 200 or 750VAC
position before connecting the test leads to 120VAC.

1) Set the range to 200VAC and measure the AC power line. The voltage should be about 120VAC. Compare

the reading to a meter of known accuracy.

2) Set the range to 750VAC and measure the AC power line. The voltage should be about 120VAC. Compare

the reading to a meter of known accuracy.

If either if the above tests fail:

a)   Check the values and the soldering of resistors R1 - R6, R16.
b)   Check that diode D1 is mounted as shown in the assembly instructions.

DC AMPS TEST

1) Set the range switch to 200

µ

A and connect the meter as in Figure 5-3. With R

A

equal to 100k

the current

should be about 90

µ

A. Compare the reading to a known accurate meter.

2) Set the range switch and R

A

as in the following table. Read the currents shown and compare to a known

accurate meter.

RANGE SWITCH

R

A

CURRENT (approx.)

2000

µ

A

10k

900

µ

A

20mA

1k

9mA

200mA

470

19mA

If any of the above tests fail:
a) Check the fuse.
b) Check the value and soldering of resistors R7, R8, and R*.

Figure 5-3

V

MA

COM

10ADC

Содержание M-1005K

Страница 1: ...DIGITAL MULTIMETER KIT MODEL M 1005K Assembly and Instruction Manual Elenco Electronics Inc Copyright 1996 Elenco Electronics Inc REV J Revised 2000 753042...

Страница 2: ...ge black yellow gold 163000 1 R25 470k 5 1 4W yellow violet yellow gold 164700 1 R23 510k 5 1 4W green brown yellow gold 165100 1 R24 820k 5 1 4W gray red yellow gold 168200 1 R17 1 2M 5 1 4W brown re...

Страница 3: ...Most capacitors will have their actual value printed on them Some capacitors may have their value printed in the following manner Second Digit First Digit Multiplier Tolerance The above value is 10 x...

Страница 4: ...ered must be heated sufficiently so that the solder flows freely Apply the solder simultaneously to the component lead and the component pad on the PC board so that good solder flow will occur Be sure...

Страница 5: ...te silver green Standard Location R 100 5 1 4W Resistor brown black brown gold see Figure B R21 220k 5 1 4W Resistor red red yellow gold see Figure B Figure C Mount the transistor with the flat side i...

Страница 6: ...Figure B R3 90k 5 1 4W Resistor white black black red green see Figure B R2A 117k 1 1 4W Resistor R2B 117k 1 1 4W Resistor R2C 117k 1 1 4W Resistor brown brown violet orange brown see Figure B R1A 27...

Страница 7: ...does not carefully slide it through the hole several times in each direction to remove any burrs Do not push on the socket leads or they may be damaged Insert the socket into the PC board holes from...

Страница 8: ...oard with two 6mm screws as shown in Figure 4 7 Insert the 25A 250V fuse into the fuse clips Your fuse may be unmarked Peel the backing off of the shield label and place it in the inside of the bottom...

Страница 9: ...CV Range 200m 0 0 0 2000m 0 0 0 20 0 0 0 200 0 0 0 1000 0 0 0 2 ACV Range 200 0 0 0 750 0 0 0 3 DCA 10A Ranges 200 0 0 0 2000 0 0 0 20m 0 0 0 200m 0 0 0 10A 0 0 0 4 Ohms Diode and hFE Ranges B indicat...

Страница 10: ...f the assembly instructions c Check the values of resistor R10 R13 R26 and potentiometer VR1 DC VOLTS TEST 1 If you have a variable power supply set the supply to about the midpoint of each of the DCV...

Страница 11: ...a source of AC voltage The AC power line is the most convenient CAUTION Be very careful when working with 120VAC Be sure that the range switch is in the 200 or 750VAC position before connecting the te...

Страница 12: ...rrent signals are conditioned by the selector switches to produce an output DC voltage with a magnitude between 0 and 199mV If the input signal is 100VDC it is reduced to 100mVDC by selecting a 1000 1...

Страница 13: ...number of clock pulses that occur during the read period During autozero a ground reference is applied as an input to the A D converter Under ideal conditions the output of the comparator would also...

Страница 14: ...utput 4 LOGIC CONTROL Internal Digital Ground 200 BACKPLANE 21 V TEST V 500 37 26 6 2V 1V Three inverters One inverter shown for clarity 40 39 38 OSC 1 OSC 2 OSC 3 DIGITAL SECTION ANALOG SECTION of 71...

Страница 15: ...simplified diagram of the AC voltage measurement function The AC voltage is first rectified and passed through a low pass filter to smooth out the waveform A scaler reduces the voltage to the DC value...

Страница 16: ...RCUIT VOLTAGE 2 8V Figure 7 8 RESISTANCE MEASUREMENT Figure 7 7 shows a simplified diagram of the resistance measurement function A simple series circuit is formed by the voltage source a reference re...

Страница 17: ...t known set the switch to the highest range 4 Connect the leads across the points to be measured and read the display If the range switch is too high reduce it until a satisfactory reading is obtained...

Страница 18: ...ates that the battery should be replaced To replace battery and fuse 250mA 250V remove the 2 screws in the bottom of the case Simply remove the old fuse battery and replace with a new fuse battery QUI...

Страница 19: ...22 21 OSC 1 OSC 2 OSC 3 TEST REF HI REF LO REF CAP REF CAP COMMON INPUT HI INPUT LO AUTO ZERO BUFFER INTEGRATOR SUPPLY G TENS C 100 s A 100 s G 100 s BACKPLANE POLARITY MINUS AB 1000 E 100 s F 100 s...

Страница 20: ...Elenco Electronics Inc 150 W Carpenter Avenue Wheeling IL 60090 847 541 3800 www elenco com e mail elenco elenco com...