background image

I N S TA L L AT I O N   M A N U A L

I N S TA L L AT I O N   M A N U A L

Please leave these instructions behind with the device

S K Y   S E R I E S

Содержание E4-16 RF

Страница 1: ...INSTALLATI O N MA NUAL INSTALLATI O N MA NUAL Please leave these instructions behind with the device S K Y S E R I E S...

Страница 2: ...INSTALLATION MANUAL i Do not use this product as a primary heat source...

Страница 3: ...LATION 8 6 1 FIRE SAFETY DEVICE SET UP 8 6 1 1 PROTECTION OF WALL AND CEILING 8 6 2 ASSEMBLY REGULATIONS 8 6 2 1 GENERAL ASSEMBLY REGULATIONS 8 6 2 2 ASSEMBLY REGULATIONS FOR NON FLAMMABLE MATERIALS 8...

Страница 4: ...ID FOR MALFUNCTION 20 A B NECESSARY TOOLS 24 B ERRORS CODES PROCONTROL APP 25 B A MESSAGES SHOWN IN APP 25 B B MESSAGES SHOWN IN REMOTE 26 C FAULTS AND ERROR CODES IN THE REMOTE 27 C A F41 ERROR 27 C...

Страница 5: ...rce This device is designed to be used with natural gas or LPG The device can only be used with the type of gas specified on the data plate at the time of purchase The device may never be used when gl...

Страница 6: ...sembly error or material defect Element4 will provide a free replacement part to the installer without compensation for disassembly or montage 5 In case the installer is not able to fix the problem hi...

Страница 7: ...ON 1 2 OFF Figure 3 1 Remote and ignition sign Figure 3 2 Gas Block Figure 3 3 Top and side view of the Receiver 4 2 IGNITING THE PILOT LIGHT Check that the control knob A is in the ON position Figur...

Страница 8: ...e in the near vicinity of the device Position the gas connection such that it is always accessible for service purposes The gas block and receiver are under the combustion chamber in the deivce so tha...

Страница 9: ...objects e g built in furniture or wooden panels are mountedonthesideofthewallthatisturnedawayfromthefireplace For these types of installations please refer to CHAPTER 6 2 3 CHAPTER 6 2 3 6 2 ASSEMBLY...

Страница 10: ...of the fireplace 200 C Table 6 1 Legenda 6 7 21 6 6 7 21 6 E d3 D F G I d1 H A2 B C d2 Figure 6 4 C31 Flue situation Flammable materials RQ 5 1 339 0 4 81 66 27 5 6 63 0 16 216 5 1 0 0 7 56 685 1 6 72...

Страница 11: ...s ventilation grills To leave out the hot air at the top of the enclosure ventilation opening are necessary Figure 6 5 The ventilation grills are to be placed at a minimal distance of 20cm from the ce...

Страница 12: ...al see APPENDIX E APPENDIX E you search for the corresponding calculation tables Each category refers to a set of tables 1 A table for horizontal outlet 2 A table for vertical outlet You must use the...

Страница 13: ...following instrucions for the installation of flue materials Drill a hole of 160 mm for the wall or roof transit with a 150 mm diameter flue connection and 210 mm with a flue with a diameter of 200 m...

Страница 14: ...is to pre set the temperature of you device for a period of one week to ensure yourself of an optimal desired room temperature Also the device can changed between high and low flames and it features a...

Страница 15: ...e the Firebed arrangements 12 Replace the access doors 13 Check the flue system and terminal making sure that the terminal vent is fully clear 14 Light the appliance and test setting pressures 15 Chec...

Страница 16: ...15 Chapter 9 INSTALLATION MANUAL Figure 9 2 Remove screws upper trim Figure 9 3 Remove upper trim Figure 9 4 Remive side trims Figure 9 5 Remove bottom trim...

Страница 17: ...16 Chapter 9 INSTALLATION MANUAL 2x2 Figure 9 6 Remove glass brackets Figure 9 7 Remove glass rope Figure 9 8 Place Suction cup on the glass Figure 9 9 Carefully lift the glas out of the fireplace...

Страница 18: ...this is the case check the burner pressure at the inlet to the burner The instructions of changing the burner pressure and the correct pressure per gastype can be found in 9 2 2 PILOT The pilot flame...

Страница 19: ...g so may cause the fire to explode on ignition 10 DECORATIVE CERAMIC PARTS This appliance is equipped with a ceramic fire bed with heat resistant ceramic fibers or artificial glassy silicate fibers Ex...

Страница 20: ...ble plus button to switch between burners Flames and soot During this first fire examine the flame for appearance and quality Flames may appear blue at first but will turn yellow after 15 to 20 minute...

Страница 21: ...turbs the reception Change the position of the antenna See Figure A B C No ignition no beep 1 Receiver defective Reset the receiver See K1 If necessary replace the receiver D No ignition receiver give...

Страница 22: ...Appendix A INSTALLATION MANUAL Figure A A Bend pin Figure A B Antenna Figure A C Torx screw Figure A D Testpoint 4 5 mV 4 5 mV Figure A E Interrupter Figure A F Wiring receiver 40mm Figure A G Pilot s...

Страница 23: ...ouple Position burner grate 3 Airflow in the burner chamber causes a restless fire image Check drain configuration Fit a flue gas limiter I Receiver gives 3 short beeps after each command 1 Batteries...

Страница 24: ...Aux position receiver AM PM ON 1 2 OFF Figure A L Double plus button on the remote Figure A M SI port PANEL G60 ZCE 1000 MA GR MO SW 2 1 3 MODE Ignition Main Burner High Flames Pilot Extinguish Main...

Страница 25: ...ed Please note If a problem is found that cannot be solved on site always contact your dealer or directly contact Element4 via our credentials which can be found on the back page of this manual 00 00...

Страница 26: ...eeps for 3 sec during motor turn Low Receiver battery power supply F10 Contact Service Pilot lit Main burner fails to ignite and pilot shuts off Ignition is blocked for 2 minutes 2nd thermocouple is o...

Страница 27: ...mmunication between Receiver and myfire Wi Fi Box F44 Contact Service No temperature shown in App N a not applicable displayed in App Handset not within range Low battery power in handset F49 Contact...

Страница 28: ...istances from occurring Many people put the router in the meter cupboard because that is where the internet comes in at many households A bad choice For a powerful WiFi signal the router needs as much...

Страница 29: ...NAL LOCATION WITH VERTICAL EXHAUST C11 Distance Exhaust 1 2 of 3 At the same roof level 6m At a different roof level 3m On a lower wall 2m On a higher sloping surface 6m Distance minimum distance requ...

Страница 30: ...V 9 O O O O O O O O V V 8 O O O O O O O O V V 7 O O O O O V V V V V 6 O O O O O V V V V V 5 O O O O O V V V V V 4 O O O O O V V V V V 3 5 O O O O O V V V V V 3 V V V V V V V V V V 2 5 V V V V V V V V...

Страница 31: ...Main 2x 320 log 1x 140 Main 2x 140 log Type of flue C11 C31 C91 Additional electricity use At rated heat output elmax 9 5 kW With minimal heat emission elmin 9 5 kW In standby mode elsb 9 5 kW Power r...

Страница 32: ...with an eco label which is always supplied with the fireplace The ecolabel shows which category the fireplace belongs to G A ECOLABELS The ecolabels for the different types of gas are indicated below...

Страница 33: ...e with some of the important dimensions that you have to take into account when installing and installing your fireplace 724 00 G 1624 00 G 199 00 134 00 1871 00 1604 00 frame 732 00 frame 172 00 105...

Страница 34: ...LLATION MANUAL 724 00 G 1624 00 G 199 00 134 00 1871 00 1604 00 frame 732 00 frame 172 00 105 00 150 00 250 00 46 00 56 00 1600 00 208 00 992 00 928 00 880 00 300 00 416 00 392 00 Figure H B Technical...

Страница 35: ...ndix H INSTALLATION MANUAL 724 00 1230 00 111 00 199 00 131 00 151 00 1461 00 1210 00 650 00 100 00 400 00 300 00 58 00 46 00 732 00 728 00 928 00 992 00 192 00 256 00 Figure H C Technical drawing of...

Страница 36: ...ndix H INSTALLATION MANUAL 724 00 1230 00 111 00 199 00 131 00 151 00 1461 00 1210 00 650 00 100 00 416 00 300 00 58 00 46 00 732 00 728 00 928 00 992 00 256 00 208 50 Figure H D Technical drawing of...

Страница 37: ...INSTALLATION MANUAL 199 00 134 00 1061 00 131 00 728 00 G 830 00 G 732 00 frame 814 00 frame 149 00 810 00 192 00 150 00 56 00 46 00 42 00 400 00 300 00 992 00 928 00 880 00 Figure H E Technical drawi...

Страница 38: ...INSTALLATION MANUAL 199 00 134 00 1061 00 131 00 728 00 G 830 00 G 732 00 frame 814 00 frame 149 00 810 00 208 00 150 00 56 00 46 00 416 00 392 00 300 00 992 00 928 00 880 00 Figure H F Technical draw...

Страница 39: ...Info element4 nl www element4 nl 19 01 22 ELEMENT 4 B V Design Assembly by RELEASE DATE...

Отзывы: