1.9.8
Interface module slot
This slot on the rear side of the device is can receive various modules of the IF-AB
interface series. The following options are available:
Figure 3
- Interface module slot
Article nr
Name
Description
35400100 IF-AB-CANO
CANopen, 1x Sub-D 9pole male
35400101 IF-AB-RS232
RS 232, 1x Sub-D 9pole male (null modem)
35400103 IF-AB-PBUS
Profibus DP-V1 Slave, 1x Sub-D 9pole female
35400104 IF-AB-ETH1P
Ethernet, 1x RJ45
35400105 IF-AB-PNET1P
ProfiNET IO, 1x RJ45
35400107 IF-AB-MBUS1P
ModBus TCP, 1x RJ45
35400108 IF-AB-ETH2P
Ethernet, 2x RJ45
35400109 IF-AB-MBUS2P
ModBus TCP, 2x RJ45
35400110 IF-AB-PNET2P
ProfiNET IO, 2x RJ45
35400111 IF-AB-CAN
CAN 2.0 A / 2.0 B, 1x Sub-D 9-pole, male
35400112 IF-AB-ECT
EtherCAT, 1x RJ45
The modules are installed by the user and can be retrofitted without problem. A firmware update of the device may be nec
-
essary in order to recognize and support certain modules.
If remote control is in operation the interface module has no priority over either the USB port or the analog interface and can,
therefore, only be used alternately to these. However, monitoring is always available.
Switch off device before adding or removing modules!
1.9.9
Analog interface
This 15-pole Sub-D socket on the back side of the device is provided for remote control
of the device via analog or digital signals.
If remote control is in operation this analog interface can only be used alternately to the
digital interface. However, monitoring is always available.
The input voltage range of the set values and the output voltage range of the monitor
values, as well as reference voltage level can be switched in the settings menu of the
device between 0-5 V and 0-10 V, in each case for 0-100%.
Figure 4 - Analog interface
1.9.10
“Share BUS” connector
The two BNC sockets (50 Ω type) labeled “Share BUS” form a digital, passed-through
Share bus. This bus is bidirectional and connects the bus master unit via “Share BUS
Output” to the next slave unit (“Share BUS Input”) etc., for use in parallel operation (mas-
ter-slave). BNC cables of suitable length can be obtained from us or electronics stores.
Basically, all 10000 series are compatible on this Share bus, though only connection
of the same device type, i. e. power supply with power supply or electronic load with
electronic load is supported by the devices for master-slave.
For a PS 10000 series device, different or identical PS 10000 series models can be
used as slave units. A PS 10000 device can furthermore be the slave of PSI 10000
series devices.
Figure 5
- Share bus