3.10.3 Method of operation
In order to understand how the function generator works and how the value settings interact, the following should
be noted:
The device always operates with the three set values U,I and P, also in function generator mode.
The selected function can be used on
one
of the values U or I, the other two are then constants and have a limiting
effect. That means, if, e.g. a voltage of 10 V is applied to the DC input and a sine wave function should operate
on the current with an amplitude of 800 A and offset 1000 A, then the function generator will create a sine wave
progression of current between 200 A (min) and 1800 A (max), which will result in an input power between 2 kW
(min) and 18 kW (max).The input power, however, is limited to its set value. If this were 15 kW then the current
would be limited to 1500 A and, if clamped to an oscilloscope, it would be seen to be capped at 1500 A and never
achieve the target of 1800 A.
Another case is when working with a function which is applied to the DC input voltage. If here the static voltage is
set higher than the amplitude plus offset then at function start there will be no reaction, as the voltage regulation
limits down to 0 with an electronic load, other than current or power. The correct settings for each of the other set
values is therefore essential.
3.10.4 Manual operation
3.10.4.1 Function selection and control
Via the touchscreen one of the functions described in
can be called
up, configured and controlled. Selection and configuration are only possible
when the DC input is switched off.
►
How to select a function and adjust parameters
1.
While the DC input is switched off tap touch area
on the main screen.
2.
In the menu overview tap on the touch area
and then on the desired function.
3.
Depending on the choice of function there follows a request to which value the function generator is going
to be applied:
or
.
4.
Adjust the parameters as you desire, like offset, amplitude and frequency for a sine wave, for example.
For the AC part of a function and if the difference between start and end value of ampli
-
tude or frequency is too low (min.
Δ
Y/
Δ
t), depending on the time that is defined for one
function run, the function generator will not accept the settings and pop up an error.
5.
Also adjust the overall limits of voltage, current and power, which you can access with touch area
.
When entering function generator mode, those global limits are reset to safe values, which
might prevent the function from working at all. For example, if you apply the selected
function to the input current, then the overall current limit should not interfere and should
at least be as high as amplitude.
Setting the various functions is described below. After setting it up, the function can be loaded.
►
How to load a function
1.
After setting the values for the required signal generation, tap on the
touch area
.
The device will then load the data into the internal controller and changes the
display. Shortly afterwards the static values are set (power and voltage or
current), the DC input is switched on and the touch area
enabled.
Only then can the function be started.