Page 43
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
EL 9000 B 15U/24U Series
3.4.3.1
Menu “General Settings”
Setting
P. Description
Allow remote control
1
Selection “
NO
” means that the device cannot be remotely controlled over either
the digital or analog interfaces. If remote control is not allowed, the status will be
shown as “
Local
” in the status area on the main display. See also section
Analog interface range
1
Selects the voltage range for the analog set input values, monitoring outputs
and reference voltage output.
•
0...5 V
= Range is 0...100% set /actual values, reference voltage 5 V
•
0...10 V
= Range is 0...100% set /actual values, reference voltage 10 V
See also section
„3.5.4. Remote control via the analog interface (AI)“
Analog interface Rem-SB
2
Selects how the input pin “Rem-SB” of the analog interface shall be working
regarding levels (see
„3.5.4.4. Analog interface specification“
•
normal
= Levels and function as described in the table in
•
inverted
= Levels and function will be inverted
„3.5.4.7. Application examples“
Analog Rem-SB action
2 Selects the action on the DC input that is initiated when changing the level of
analog input “Rem-SB”:
•
DC OFF
= the pin can only be used to switch the DC input off
•
DC AUTO
= the pin can be used to switch the DC input off and on again, if it
has been switched on before at least from a different control location
DC input after power ON
3
Determines the condition of the DC input after power-up.
•
OFF
= DC input is always off after switching on the device
•
Restore
= DC input condition will be restored to the condition prior to switch off
Voltage controller setting
3
Selects the regulation speed of the internal voltage regulator between “
Slow
”
and “
Fast
”. See
„3.2.1.1. Speed of the voltage controller“
.
DC input after PF alarm
4 Determines how the DC input shall react after a power fail (PF) alarm has
occurred:
•
OFF
= DC input will be switched off and remain until user action
•
AUTO
= DC input will switch on again after the PF alarm cause is gone and
if it was switched on before the alarm occurred
DC input after remote
4
Determines the condition of the DC input after leaving remote control either
manually or by command.
•
OFF
= DC input will be always off when switching from remote to manual
•
AUTO
= DC input will keep the last condition
Enable R mode
5
Activates (“
Yes
”) or deactivates (“
No
”) the internal resistance control. If activated,
the resistance set value of the simulated internal resistor can be adjusted addi
-
tionally to the other set values. For details refer to
USB file separator format
6 Switches the decimal point format of values and also the CSV file separator for
USB logging and for other features where CSV file can be loaded
US
= Comma separator (US standard for CSV files)
Default
= Semicolon separator (german/european standard for CSV files)
USB logging with units
(V,A,W)
6 CSV files generated from USB logging by default add physical units to values.
This can be deactivated by setting this option to “
No
”
Calibrate device
7 Touch area “
Start
” starts a calibration routine (see
), but only
if the device is in U/I or U/P mode.
Reset device to defaults
8
Touch area “
Start
” will initiate a reset of all settings (HMI, profile etc.) to fac
-
tory default, as shown in the menu structure diagrams on the previous pages
Restart device
8
Will initiate a warm start of the device
Master-slave mode
9
Selecting “
OFF
” disables the master-slave mode (MS) in which the cabinet
is running by default. Since the MS mode is essential for the operation of the
cabinet, this setting should never be altered.