User Manual

Interface Cards

USB / RS232 / GPIB /

CAN / Analog / Ethernet /

Profibus

IF-U1 (USB):

33 100 212

IF-U2 (USB):

33 100 220

IF-R1 (RS232):

33 100 213

IF-R2 (RS232):

33 100 221

IF-C1 (CAN):

33 100 214

IF-C2 (CAN):

33 100 222

IF-A1 (ANA):

33 100 215

IF-E1B (Ethernet): 33 100 227

IF-G1 (GPIB):

33 100 216

IF-E2B (Ethernet): 33 100 228

IF-PB1 (Profibus): 33 100 219

Содержание 33 100 212

Страница 1: ...Profibus IF U1 USB 33 100 212 IF U2 USB 33 100 220 IF R1 RS232 33 100 213 IF R2 RS232 33 100 221 IF C1 CAN 33 100 214 IF C2 CAN 33 100 222 IF A1 ANA 33 100 215 IF E1B Ethernet 33 100 227 IF G1 GPIB 33...

Страница 2: ...rmation see section 3 3 Combining interface cards Never remove the covers from the cards If only one card is equipped in units with two slots it is recommended to install the default slot cover to the...

Страница 3: ...000 series 13 7 3 2 Analogue outputs 13 7 3 3 Digital inputs 14 7 3 4 Digital outputs with determined functionality 15 7 3 5 Digital outputs with user definable functionality 16 8 GPIB card IF G1 17 8...

Страница 4: ...bout particular device series 24 11 1 Series EL 3000 EL 9000 24 11 2 Series PS 8000 T DT 2U 3U 24 11 3 Series PSI 800 R and BCI 800 R 24 12 The System Link Mode PSI9000 only 25 12 1 Handling the Syste...

Страница 5: ...r web site ZIP file with instruction manuals for all interface cards The voltage range of the analogue input and output signals of the IF A1 is customisable between 0 and 10V The digital inputs can be...

Страница 6: ...ation settable in the unit s menu CAN standard V2 0 part A About the interface cards IF A1 Analogue Electrical isolation 2000V DC Analogue inputs Input voltage range Maximum range 5V 15V Nominal range...

Страница 7: ...physical damage If any damage can be found do not use and insert the card into any device 3 2 Inserting a card The card s must only be inserted while the unit is completely switched off The unit does...

Страница 8: ...guration card s menu If two are equipped PSI 9000 each card has to be configured individually You can now setup the parameters device node Default 1 1 30 Choose one of up to 30 device nodes Baud rate...

Страница 9: ...rate setting the so called Sample point can be chosen which is used to optimise the data transmission for various cable lengths and qualities It adjusts the point of time when a transmitted bit is sa...

Страница 10: ...very device node is occupy ing another two addresses RID 64 device node 2 and RID 64 device node 2 1 Example the RID was set to 13 the device address node to 12 In order to control the device the iden...

Страница 11: ...ls and VREF 16 17 N C 18 AO0 VREF Analogue output Reference voltage 10V Accuracy typ 0 1 1 Imax 8mA 4 Short circuit proof against GND 19 VCC Auxiliary voltage Reference DGND 12V 16V Imax 50mA4 Short c...

Страница 12: ...e 7 3 Configuring the IF A1 The interface is configured in the communication menu With M Communication and Slot A B IF A1 the analogue interface card is selected for configuration Following parameters...

Страница 13: ...3000W power at 8V input on PSEL but only 50A when you supply 8V on CSEL input At 4V on CSEL it will put out max 25A 7 3 1 2 PSI 8000 series Note PSI 8000 series models of type T DT 2U or 3U feature a...

Страница 14: ...ls and analogue actual values are always put out About the interface cards Input DI2 Rem SB You can switch the power supply output on and off enable or block it with this input Depending on the settin...

Страница 15: ...choose setting Set output exclusive ON Example 1 the input shall be pulled to GND by a relay maker contact and switch the power output off Hence you need to configure the jumper for DI2 to Default le...

Страница 16: ...tions can be assigned to each of the outputs remote Indicates that the power supply is remotely controlled via a digital interface card OT Indicates an overtemperature error CP Indicates that the powe...

Страница 17: ...card carefully into the device again and connect the Sub D plug to a PC via a 9pole Sub D cable of null modem type not included A separately obtainable update tool can either be downloaded from your...

Страница 18: ...oring can be inhibited by local mode being active see device manual about local mode When communicating with the device via TCP IP the web site should be closed because the website generates ad dition...

Страница 19: ...ps 1 Connect the Ethernet card via patch cable to a PC and access the current IP with a browser Chrome Firefox IE In case the card was not set to a custom IP before the default IP is 10 0 0 1 2 The br...

Страница 20: ...port selection for TCP IP communi cation 9 3 2 Communication in LabView LabView has implemented VIs for interface communication via TCP IP VISA by default These can be used according to their given ha...

Страница 21: ...fective or the card is not installed correctly 2 The IP is a different network segment A subnet mask defines what local IPs are accessible in the network The subnet mask as set for the IF E1B Ethernet...

Страница 22: ...ut of 125 Profibus addresses can be selected 10 3 Connecting the bus The unit is connected to the bus master or to other units with a typical Profibus cable Those cables are required to have a built i...

Страница 23: ...o be reconfigured during the update process This is what the last position 2nd Prog is used for The required Update Tool will lead you through the update process and request you to do the necessary se...

Страница 24: ...ipped a different selection of parameters is available The parameters and their values are identical to the ones explained in section 4 to 8 with the exception that no Sample point can be set at CAN T...

Страница 25: ...not recommended to link more than 10 units when using parallel connection Example Four devices PSI 9080 100 shall be linked Each of them can deliver 3kW power If you serially connect two sets of units...

Страница 26: ...emperature has disappeared and the power stage is cooled down Auto ON The power output is automatically switched ON again after the overtemperature has disappeared and the power stage is cooled down S...

Страница 27: ...one of the digital interface cards can i e remote control be found in external user guides which are separated into Programming Object lists SCPI command lists The user guide Programming contains all...

Страница 28: ...The connectors of the CAN card are connected in parallel Note about IF U1 IF R1 The System Link ports are only usable with power supplies of the series PSI9000 Never connect Ethernet cables here CAN1...

Страница 29: ...29 User Manual Interface cards IF XX EN Date 22 10 2015 LAN USB A Reset USB A USB A Profibus Status IF E1B IF E2 IF R2 IF U2 IF PB1 Overviews...