13
Gutter holder
GH-2
Heating cable fixing in gutters and downpipes
Gutters
Heating cables should be fixed in order to maintain
steady spacing between neighbouring cable’s seg-
ments.
Heating cables can be fixed with holders (holder
spacing should not exceed 30 cm) or a wire with
clips.
If the water from downpipes is discharged
directly to the rain channel, the segment
of the downpipe from the surface level to
the soil freezing depth als should be
heated.