background image

 

Page 11 of 24                                                                                                                                                     M7044 iss 3.3 

 

 

7.3.  Connect to the mains electricity supply. Observe the white neon lamp is illuminated showing 

the presence of mains electricity. 

 

7.4.  Switch the controller on by turning the regulator control knob clockwise to increase power. 

The amber neon lamp on the controller will pulsate to show that power is being supplied to 
the mantel, heating tape or cord etc. The frequency of the pulse will increase as the regulator 
control knob setting is increased. At maximum setting the amber neon will be continually 
illuminated. 

 

7.5.  When your process is complete, switch off the controller and disconnect it from the mains 

electricity supply.  

 

Always take suitable handling precautions when moving / touching hot glass 

vessels and solutions. 

 

7.6.  Always refer to the Instruction book of the equipment to be used. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MC5

Страница 1: ...Page 1 of 24 M7044 iss 3 3 MC5 CONTROLLER INSTRUCTION BOOK ...

Страница 2: ...eclaration of Conformity Page 24 Appendix A Decontamination Certificate Page 19 The copyright of this instruction book is the property of Bibby Scientific Limited This instruction book is supplied by Bibby Scientific Limited on the express understanding that it is to be used solely for the purpose for which it is supplied It may not be copied used or disclosed to others in whole or part for any pu...

Страница 3: ...pes and Cords for bench top operation delivering up to a maximum of 800Watts 1 2 A rod support clamp is provided at the rear of the controller to take a standard 12 5mm I 2 diameter rod 1 3 The MC5 has a short mains output lead with an IEC socket to connect it to the resistive load An accessory extension mains lead is available where remote operation is required e g in a fume extraction unit ...

Страница 4: ...one s self or other people The Responsible Body and the Operator should read and be familiar with this Instruction book in order to preserve the protection afforded by the equipment To prevent injury or equipment damage it is the manufacturer s recommendation that all persons using this equipment are suitably trained before use 2 2 Symbols Defined Caution risk of danger See note or adjacent symbol...

Страница 5: ...s supply voltage is correctly earthed grounded in accordance with current area legislation Do not install or remove any heating apparatus from the controller whilst power is applied 3 2 General safe Operating Practice Always follow good laboratory practice when using this equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation...

Страница 6: ...point substances away from heating apparatus Do not operate or handle any part of this product with wet hands Do not leave this product switched on without glass sides in place for prolonged periods Keep the Mains Plug and Lead set cable away from the heating apparatus being controlled Refer to Instructions book product data label for the resistive load of equipment to ensure controller is suitabl...

Страница 7: ...iagram Mains plug and cord set may differ from illustration Contents Item Description Qty 1 Control unit 1 2 Moulded mains cord and plug set May be different to illustration 1 3 Instructions book this document 1 For future reference please record your products Serial and Model Numbers Serial Number Model Number ...

Страница 8: ... only the correct rated mains input fuses are fitted Where applicable ensure the correct mains cable fuse if fitted See Technical Information Section 8 of this Instruction book 5 5 Check the voltage on the product data label of this unit Ensure the rating conforms to your local supply If an 115V product is used in a 230V supply area then a 230 115V transformer must be installed between the 230V ma...

Страница 9: ...er information For end users outside of the EU consult applicable regulations 6 4 This product should only be dismantled for recycling by an authorised recycling company his product and accessories must be accompanied by a completed Decontamination Certificate prior to any disposal Copies of the Certificate are available from your distributor of Bibby Scientific products or you may copy and enlarg...

Страница 10: ...th continuity test point 3 Data plate label See for correct voltage type 4 Mains Output IEC plug 5 Rod support clamp 6 Mains power on neon lamp White 7 Mantle Bunsen heaters on neon lamp Orange 8 Regulator control knob Check the dataplate label and ensure your mains electrical supply voltage is compatible with this product 7 2 Connect the IEC output plug to your heating apparatus product as illust...

Страница 11: ... show that power is being supplied to the mantel heating tape or cord etc The frequency of the pulse will increase as the regulator control knob setting is increased At maximum setting the amber neon will be continually illuminated 7 5 When your process is complete switch off the controller and disconnect it from the mains electricity supply Always take suitable handling precautions when moving to...

Страница 12: ...supply cord H05 V V F Replace only with equivalent cable 13A BS1362 Mains cord and moulded IEC plug and lead set cable Europe AZ6747 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord H05 V V F Replace only with equivalent cable Mains cord and moulded IEC plug and lead set cable USA AZ6746 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord SJT ...

Страница 13: ...d include Periodic electrical safety testing an annual test is recommended as the minimum requirement Regular inspection for damage with particular attention to the mains lead and plug set Routine cleaning of the equipment should be undertaken using a clean cloth Check the ventilation slots are clear DO NOT USE SOLVENTS FOR CLEANING ANY PART OF THIS EQUIPMENT 9 2 Replacing controller fuses The mai...

Страница 14: ...ntroller up side down and remove the two fixing screws retaining the base Lift the base off 9 3 4 Disconnect the tagged wires one at a time from old and connect to the new energy regulator Refer to wiring diagram Reassemble 9 3 5 Position new energy regulator and then fit and tighten the shake proof washer and the locknut ...

Страница 15: ... it from any heating resistive loads such as Heating Mantles Heating Tapes and Cords 9 4 2 Turn the Controller up side down and remove the two fixing screws retaining the base Lift the base off 9 4 3 Disconnect the two wires from the relavent neon 9 4 4 Push the neon out from the inside Note a slight twisting movement may be necessary Reassemble 9 4 5 Insert the new neon ensuring the tags align wi...

Страница 16: ...e strain relief bush from inside 9 5 6 Remove the Mains output cable 9 5 7 Relocate the stain relief bush around the new Mains output cable with the smaller diameter towards and approximately 10mm from end of the cable outer sleeve 9 5 8 Squeeze the bush and align the flats to locate through the aperture in the backplate Note a reasonable amount of force may be required 9 5 9 Check the fitting by ...

Страница 17: ...ation should only be undertaken under the control of the Responsible Body with due recognition of possible hazards Before using any cleaning or decontamination method the Responsible Body should check with the manufacturer the proposed method will not damage the equipment Prior to further use the Responsible Body shall check the electrical safety of the unit Only if all safety requirements are met...

Страница 18: ...ritain Tel 44 0 1785 812121 Fax 44 0 1785 810405 General enquiries info bibby scientific com Order enquiries sales bibby scientific com Technical support electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9243Tel 609 589 2560 Fax 609 589 2571 Email labproducts techne...

Страница 19: ...leting YES NO as applicable and by providing details in section 2 below A Blood body fluids Pathological specimens YES NO Provide details if YES B Biodegradable material that could become a hazard YES NO Provide details if YES C Other biohazard YES NO Provide details if YES D Chemical or substances hazardous to health YES NO Provide details if YES E Radioactive substances State name s and quantiti...

Страница 20: ...Page 20 of 24 M7044 iss 3 3 11 SPARES AND ACCESSORIES Neon Clear CRM5607 Amber CRM5608 Extension Lead M6332 Europe M6902 UK Plug and lead set UK AZ9165 Plug and lead set USA AZ6746 ...

Страница 21: ...Page 21 of 24 M7044 iss 3 3 12 NOTES ...

Страница 22: ...Page 22 of 24 M7044 iss 3 3 ...

Страница 23: ...Page 23 of 24 M7044 iss 3 3 ...

Страница 24: ...fic Limited Beacon Road Stone Staffordshire ST15 0SA Great Britain Tel 44 0 1785 812121 Fax 44 0 1785 810405 General enquiries info bibby scientific com Order enquiries sales bibby scientific com Technical support electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 92...