background image

广州谐同电子科技有限公司 Guangzhou Electrony Corporation

 

 
 
 
 
 
 
 
 
 

                                   

 

 

                                                                                   

 

                 

用户手册

 

                         

                  

   

User Manual 

 

 

S-LCD3 eBike Special Meter 

 

 
 
 

 
 
 
 

WWW.ELECTRONY.CN

Содержание S-LCD3

Страница 1: ...Guangzhou Electrony Corporation User Manual S LCD3 eBike Special Meter WWW ELECTRONY CN...

Страница 2: ...22 2 handlebar diameters install icon 5 Physical installation icon 6 Function Overview 6 Display Content 7 Button Definition 7 Normal Operation 7 On Off 7 Display Interface 8 Display 1 8 Display 2 9...

Страница 3: ...ignal Setting Mode 20 P3 Power Assist Control Mode 21 P4 Handlebar Startup Mode 21 P5 Power Monitoring Mode 22 Exit P Parameter Setting 23 C Parameter Setting 23 C1 Power Assist Sensor and Parameter S...

Страница 4: ...C12 Controller Minimum Voltage Adjustment Mode 32 C13 ABS brakes of the controller and parameters of anti charge control 34 C14 Power assist tuning parameters 35 Exit C Parameter Setting 35 Parameter...

Страница 5: ...parameters how to achieve the best match of the three as motor controller and meter to improve electronic control performance of the electric motor This manual covers installation operation parameter...

Страница 6: ...on box are mounted on the handlebars of the electric vehicle adjusting perspective In the case that the vehicle is power off the meter connectors are in plug connection to corresponding controller con...

Страница 7: ...MPH and a single maximum speed MXS and a single average speed AVS Trip distance display with displays of a single trip distance DST and total trip distance ODO Display of turned on handlebar Display o...

Страница 8: ...ere are three keys on the operating panel of button box which are icons of button alt text UP button alt text SW and alt text DOWN Button Box and Operating Panel Normal Operation On Off Hold button SW...

Страница 9: ...powered off In power off mode the power consumption of the meter and controller is zero Display Interface Display 1 The meter is startup to enter display 1 Display 1 The followings are shown on displ...

Страница 10: ...nvironment Temperature Backlights and Headlights Status Brake Status Cruise Function CRUISE Motor Running Temperature Display 2 In display 1 hold button SW shortly to enter display 2 Display 2 The fol...

Страница 11: ...display 1 the original motor power is replaced by motor running temperature as is shown in Figure Display 3 In display 2 hold button SW shortly to enter display 3 Display 3 The followings are shown on...

Страница 12: ...lebar Rotate the handlebar under normal operating of the meter the display interface shows the sign of turned on handlebar see the Figure below The sign will be off automatically after about five seco...

Страница 13: ...for the lowest power and gear 5 is for the highest power At every startup the meter will automatically restore gear this can also be configured as required by users when it was at last shut down When...

Страница 14: ...ights as well as the vehicle headlights the Controller should have headlights driving and output functions meter backlighting and vehicle lights power logo light hold button UP long again to turn off...

Страница 15: ...utdown currently Voltage shortage flashes Battery capacity indicator Motor Operating Power and Temperature Under the riding status of vehicle the real time running and output power can be known via th...

Страница 16: ...nment temperature display The temperature display value may be in deviation shortly after boot up and the display value will be gradually approaching the environment temperature within 10 minutes afte...

Страница 17: ...Definition Table Error Code Definition 01 info Throttle Abnormality 03 info Motor Hall Signal Abnormality 04 info Torque sensor Signal Abnormality 05 info Axis speed sensor Abnormality only applied t...

Страница 18: ...ing Setting interface of maximum trip speed Under the setting maximum riding speed interface if there s no button operation on the meter for more than 1 minute and then the meter will automatically re...

Страница 19: ...r into the next setting Metric and Imperial Units After finishing the wheel diameter setting enter into the metric imperial units setting interface and then the speed and mileage unit flash Hold butto...

Страница 20: ...environment and return to display 1 meanwhile the current set parameters are saved Under each setting interface if there s no button operation on the meter for more than 1 minute and then the meter wi...

Страница 21: ...erface after P1 parameter setting is finished and P2 parameter column flashes P2 parameter setting interface P2 is wheel speed pulse signal setting mode If wheel generated 1 pulse signal by a revoluti...

Страница 22: ...tting interface after P2 parameter setting is finished and P3 parameter column flashes P3 parameter setting interface P3 is for power assist control mode when P3 parameter setting is1 power assist con...

Страница 23: ...interface P5 is power monitoring mode when P5 setting is 0 the power monitoring is the real time voltage mode Namely it is the method to determine the battery capacity based on real time battery volta...

Страница 24: ...ishing P5 parameter setting P5 parameter column stops flashing Within 1 minute after stopping flashing hold button UP and button DOWN for about 2 seconds to enter C parameter setting environment C1 Po...

Страница 25: ...meter setting interface after C1 parameter setting is finished C2 parameter column flashes C2 parameter setting interface C2 is motor phase classification coding mode It is served as identification pa...

Страница 26: ...r is switched on and the power assist ratio is at gear 0 When the setting is 1 the meter is powered on and the power assist ratio is at gear 1 and so on After finishing C3 parameter setting hold butto...

Страница 27: ...according to the display meter Handlebar gears is distinguished according to the display meter 5 Retain Retain After finishing C4 parameter setting hold button SW shortly to save the current set value...

Страница 28: ...t value when setting is 9 maximum current value divided by 1 10 when setting is 8 maximum current value divided by 1 15 and so on After finishing C5 parameter setting hold button SW shortly to save th...

Страница 29: ...e after C6 parameter setting is finished C7 parameter column flashes C7 parameter setting interface C7 is cruise function setting mode The setting range is 0 or 1 hold button UP or button DOWN shortly...

Страница 30: ...on Please Note The motor operating temperature display requires installing temperature sensor in the motor output temperature detection signal simultaneously After finishing C8 parameter setting hold...

Страница 31: ...is done sequentially from left to right hold button shortly to confirm after each setting and enter next setting Password setting range is 000 999 hold button UP or button DOWN shortly for selection P...

Страница 32: ...s needed to restore default setting C10 selects y hold button long for about 2 seconds all parameters restore default settings and exit setting environment and then return to the display1 C10 selects...

Страница 33: ...r transfers the new LD3 parameter to other meters C11 selects 2 hold SW long for about 2 seconds to exit the setting environment and then the meter is served as data source for copying parameter see p...

Страница 34: ...alue 2V Default value 2V 1 Default value 1 5V Default value 1 5V Default value 1 5V 2 Default value 1V Default value 1V Default value 1V 3 Default value 0 5V Default value 0 5V Default value 0 5V 4 De...

Страница 35: ...3 parameter definition table C13 Value ABS braking strength Energy recovery efficiency 0 None None 1 Class 1 braking strength Best energy recovery efficiency 2 Class2 braking strength General energy r...

Страница 36: ...utton SW shortly to save current set values and enter C1 parameter setting interface again Or hold button SW long for about 2 seconds to exit C parameter setting environment and return to the display...

Страница 37: ...opy wiring diagram Special wiring cable Turn on meter power supply of data source Power supply of 48V or 36V or 24V is available VB positive power supply After wiring the meter needs to be copied hold...

Страница 38: ...he user setting environment if there s no button operation on the data for more than 1 minute the meter will automatically return to display1 and the new set parameters won t be saved The factory para...

Отзывы: