42
Program unit
TEMP CONTROL WATER
Select whether the machine is to control and adjust the water temperature
by opening and closing the main valves for hot and cold water during fil-
ling.
Yes =
Control of main valves during filling.
- Alt.1: Hot and cold water valves both open. If the set water tem-
perature is exceeded, the hot water valve will be shut automati-
cally.
- Alt. 2: Only hot water valve open. If the set water temperature is
exceeded, the cold water valve opens automatically together with
the hot water valve.
No =
No temperature control. The hot and cold water valves are both
open until the correct level has been attained.
SHOW °C
Select whether all the temperature values are to be displayed in °C or °F
Yes =
All temperature values displayed in °C.
No =
All temperature values displayed in °F.
DELAYED START
Select whether there should be the possibility of setting a delay from when
the start button is pressed until the machine is to start.
Yes =
Time for delayed start can be set. Delayed start is available as a se
parate menu bar in the start menu, where you can select the delay
in hours and minutes.
No =
The delayed start function is disengaged.
AUTO RESTART
Select whether there should be the possibility of setting the machine for
automatic restart. Automatic restart is available as a separate menu in the
start menu, where the number of automatic restarts of the selected wash
programme can be selected by the user.
Yes =
Number of automatic restarts can be set.
No =
The delayed start function is disengaged.