Fresh air intake
At regular basis, check that the fresh air intake on the front of the machine is not clogged by lint and dust or otherwise
blocked.
Clean with a vacuum cleaner.
fig.7386
5.5
Machines with residual moisture control (RMC)
At regular basis, wipe off/clean drum and lifters with citric acid (Acidum citricum). If soap/softener residue remains, it
is recommended also to use a coarse sponge.
Lack of cleaning can reduce the automatic residual moisture control which will make the load more moisture than re-
quested when the program has ended.
5.6
Condensate machine
At regular basis, clean the condensing unit from dust and lint.
Remove the condensing unit from the machine and clean it by rinsing it with water. Make sure all dust and lint is
removed.
Clean the area where the air condenser is placed in the machine.
fig.7160A
5.7
Maintenance to be carried out by qualified service personnel
Contact qualified service personnel to perform the following maintenance:
After 1600 hours of operation or once a year, whichever comes first:
• Clean the fan, the exhaust duct and the fresh-air intake to the room
• On machines with RMC: Clean the glide surface on the RMC graphite collector
• Clean the area around the drum
• Clean the motors
• Check the belt tension