9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G30/G31 (3B/P) 30/30
mbar
567 g/h
Gas replace‐
ment:
G20 (2H) 20 mbar
7,65 kW
Electric supply: 220-240 V ~ 50-60 Hz
Appliance cate‐
gory:
II2H3B/P
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for LPG G30/G31 30/30 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Rapid
2,8
0,95
86
204
Semi-rapid
2,0
0,6
71
145
Auxiliary
1,0
0,33
50
73
9.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid
2,95
0,75
119°
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
10. ENVIRONMENTAL CONCERNS
Recycle materials with the symbol .
Put the packaging in relevant containers
to recycle it. Help protect the
environment and human health by
recycling waste of electrical and
electronic appliances. Do not dispose of
appliances marked with the symbol
with the household waste. Return the
product to your local recycling facility or
contact your municipal office.
Electrolux Appliances AB - Contact
Address: Al. Powstańców Śląskich 26,
30-570 Kraków, Poland
*
ENGLISH
17
Содержание KGS6424X
Страница 1: ...KGS6424X EN Hob User Manual ...
Страница 18: ......
Страница 19: ......
Страница 20: ...www electrolux com shop 867356378 C 232021 ...