16
Installation
INSTALLING THE DOWNDRAFT VENT
Loosely attach the anchoring legs to the left and right sides of the plenum using the
hex nuts provided. Place the vent into the rear of the countertop cutout. Adjust the
anchoring leg height so that the end caps are gently resting on the counter, then
tighten the hex nuts. Secure the anchoring legs to the cabinet/floor with the screws
provided.
CONNECTING THE EXHAUST DUCT
For the side or bottom knockouts use the supplied transition. For the rear knockout
attach a 3 1/4" x 10" duct.
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT
ANT
ANT
ANT
ANT
The vent must be installed in a vertical orientation. Do not mount the vent on a slant or
angle.
Remove the knockout from the plenum by cutting the tape and metal cross overs to
remove the insert.
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT
ANT
ANT
ANT
ANT
Use duct tape and sheet metal screws to seal the connection between the blower outlet
and duct. Support the duct weight as necessary to ensure sealed joints.