SERVICE MANUAL

© AEG Hausgeräte GmbH

Muggenhofer Straße 135
D-90429 Nürnberg
Germany

Fax +49 (0)911 323 1420

TSE - N
Ausgabe:

11.98

Edition:

11.98

Publ.-Nr.:
599 50 66 51
685

Dishwasher

Fully electronic dishwasher

FAVORIT 8081

EN

DISHWASHER

Содержание FAVORIT 8081

Страница 1: ... AEG Hausgeräte GmbH Muggenhofer Straße 135 D 90429 Nürnberg Germany Fax 49 0 911 323 1420 TSE N Ausgabe 11 98 Edition 11 98 Publ Nr 599 50 66 51 685 Dishwasher Fully electronic dishwasher FAVORIT 8081 EN DISHWASHER ...

Страница 2: ...tion as the range 1995 like shown on the pages 292 1372 01 21 But it has a bigger electronic with automatic programes In the automatic programes the pollution mist of the rinse water is measured during the pre rinse and the intermediate rinse If no pollution is recognized the water of the pre rinse is used during the mainwash A second intermediate rinse will not be executed ...

Страница 3: ...put voltage corresponding to the turbit with automatically engage the electronical output according to the output voltage until it has reched 4 3 V This calibration occurs in final rinse Should the maximum input voltage of 11 4 V be reached then it couldn t reach the output voltage of 4 3 V 60 mV The error will be recorded C5 in the memory Should the output voltage in pre wash be under 3 V and in ...

Страница 4: ... distributor out of power heating till 50 C distributor power on 1 min distributor position on upper sprayarm distributor out of power heating till 60 C ECO Program 65 C Normal Program 70 C Intensiv Program distributor power on washing predominant on lower sprayarm Final rinse distributor position on upper sprayarm distributor out of power heating till 50 C dosage rinse aid distributor power on do...

Страница 5: ...nical Data Autoprogram AUTO 65 and AUTO BIO 50 excample for program without sensorlogic full load turbit turbit no turbit turbit no turbit no turbit washing washing final rinse extra intermediate rinsing of softener upon regenerating of softener 4 min pre wash 6 min 3 min 5 min 1 and 2 turbitidy 3 and 4 40 sec calibrate ...

Страница 6: ...UTO 65 and AUTO BIO 50 Example for program with sensorlogic half load no turbit turbit noticed 2000 U min 2000 U min intermediate rinsing rinsing of softener upon request 4 min pre wash 6 min 1 and 2 turbitidy measurement washing regenerating of softener upon request 40 sec Calibrate on 4 3V final rinse with rinse aid half loading heating 50 C ...

Страница 7: ...yarm The position contact for distributor b65 is open After change the upper sprayarm will be controlled within 40 sec During this 40 sec should be existing minimal 4 impulse If that is not the case an error will be recorded as Cu in the memory The LED sprayarm is on and the buzzer is going on LED water inlet The reed relay for water inlet is removed Function The inspect of LED water inlet occurs ...

Страница 8: ...sing the heater power after 6 seconds the display is switched off and the power value is stored 2 Fault display If the electronic detects a fault during the washing programme it is displayed by flashing LEDs By pressing the programme button next to the LED the programme continues and the fault display is cancelled The lower 5 LEDs of the programme progress indicator are used for the fault display ...

Страница 9: ...ult memory NTC Temperature sensor Interruption short circuit Program keeps on running without heater Voltage measurement at NTC temperature sensor X X C9 only in fault memory Tacho generator faulty Program keeps on running Recycling pump on nominal speed Electronic module does not detect tacho information X X CA Short circuit in Triac for recycling pump on left module Program is skipped up to end ...

Страница 10: ...utton 3 all LEDs illuminate the fault memory is deleted 5 Test of individual components Whilst pressing buttons 2 and 3 simultaneously and switch on with button 1 In display d1 Button 1 On Button 4 recycling pump Button 2 admission valve Button 5 rotary slide Button 8 Fan flap Button 3 regeneration valve Button 6 drain pump Button 9 detergent dispenser 20 sec after pushing the latest button the pr...

Страница 11: ... 3 seconds draining until reset position pressure switch draining 30 seconds Rotary switch until position upper spray arm filling until switch position pressure switch filling 19 5 Sekunden Washing filling recycling until switch position pressure sensor Detergent cover recycling 5 seconds heating recycling Rotary switch 65 C draining until reset position pressure switch draining 30 seconds Regener...

Страница 12: ...rstellbar The electronic regeneration dosage can be adjusted to 10 different settings o Die Taste und gleichzeitig drücken o press the and buttons next to the display simultaneously o Im Display erscheint die eingestellte Stufe H0 H9 o the display show s the setting H0 H9 o Mit den Tasten oder kann die Stufe verändert w erden o the setting can be ajusted w ith the or button Härtebereich Härteberei...