Страница 1: ...EN AIR CONDITIONER USER MANUAL 2 EPM09CRC A1 EPM12CRC A1 ...

Страница 2: ... our Authorised Service Centre ensure that you have the following data available Model PNC Serial Number The information can be found on the rating plate Subject to change without notice Warning Caution Safety information General information and tips Environmental information Australia www electrolux com au New Zealand www electrolux co nz Visit our website to CONTENTS 1 SAFETY INFORMATION 3 2 SAF...

Страница 3: ...g the product This manual should be kept in a safe place for handy reference Symbol Note Explanation WARNING CAUTION CAUTION CAUTION This symbol shows that this appliance uses a flammable refrigerant If the refrigerant is leaked and exposed to an external ignition source there is a risk of fire This symbol shows that the operation manual should be read carefully This symbol shows that a service pe...

Страница 4: ...side to direct sunlight and rain 4 Always store or move the unit in an upright position 5 Do not cover the appliance when in operation or immediately after use 6 Always drain condensation before storing unit 7 The appliance shall not be installed in the laundry There are local council rules regarding maximum allowable noise levels emitted by air conditioners If the power cord is to be replaced rep...

Страница 5: ...st be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Use only the manufacturer specified power cord for replacement This appliance must be earthed This appliance is equipped with a cord having an earth wire The plug must be plugged into an outlet that is properly installed and earthed Do not under any circumstances cut or remove the ear...

Страница 6: ... Cooling performance may be reduced or stop completely Provide a anti explosive residual current device RCD in order to protect against electric shock in accordance with Australian Standard and Wiring Rules Exposure to direct airflow for an extended period of time could be hazardous to your health Do not expose occupants pets or plants to direct airflow for extended periods of time Do not use this...

Страница 7: ...the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters stoves or other sources of ignition The appliance must be stored in such a way as to prevent mechanical failure Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by a...

Страница 8: ... instructions may cause harm or damage The seriousness is classified by the following indications This symbol indicates the possibility of death or serious injury Warning during usage This symbol indicates the possibility of injury or damage to property WARNING WARNING CAUTION Meanings of symbols used in this manual are shown below This symbol indicates never to do this This symbol indicates alway...

Страница 9: ...stall circuit breaker and a dedicated power circuit Incorrect installation may cause electric shock fire and explosion Unplug the unit if strange sounds smell or smoke comes from it It may cause electric shock fire and explosion Do not use the socket if it is loose or damaged It may cause electric shock fire and explosion Do not open the unit during operation It may cause electric shock fire and e...

Страница 10: ... household furniture Hold the plug by the head of the power plug when taking it out It may cause electric shock and damage Turn off the main power switch when not using the unit for a long time It may cause failure of product or fire and explosion Do not place obstacles around air inlets or inside of air outlet It may cause failure of appliance or accident Always insert the filters securely Clean ...

Страница 11: ...outlet Bottom drain outlet Pump drain outlet 4 ACCESSORIES Check all the accessories are included in the package and please refer to the installation instructions for their usage Fasters foam seal or any other accessories you may need in the installation should be sourced locally 1 2 3 4 5 PARTS PARTS NAME QUANTITY Adaptor A Exhaust duct Adaptor B flat mouth Window Slider Kit Drain hose Remote con...

Страница 12: ...side of the hose Fig 1 and screw the hose to adaptor A Fig 2 3 Install the adaptor A into the unit Fig 4 Fig 4 2 Extend the other side of the hose and screw it to adaptor B Fig 3 Fig 1 Lock 2 Insert 1 The adaptor A already be screwed to the hose for this unit Fig 6 1 Fig 5 Fig 6 2 The hose can be extended from its original length of 38cm up to 150cm but it is the best to keep the length to minimum...

Страница 13: ...Vinyl Clad windows Use 12 7 hex head cap screws for securing 7 Cut the Foam seal to an appropriate length and seal the open gap between the top window sash and outer window sash as shown in Fig 13 source locally 6 To secure lower sash in place attach right angle Sash lock with 12 7mm screw as shown Fig 12 3 Close the window sash securely against the window slider kit Fig 11 Cut the adjustable wind...

Страница 14: ...der kit according to the height of window Screw down the two screws on the window slider kit See Fig 15 Cut the adjustable window slider kit if the height of window is less than 67 5cm Fig 10 3 Close the window sash securely against the window slider kit Fig 16 4 Drive two 12 7mm screws to secure the window slider kit to the window sash Fig 16 5 Drive two 19mm screws to secure the window slider ki...

Страница 15: ...o choose the temperature you want 1 Press the mode button until the Heat indicator is lit 2 Press the fan speed button to choose the fan speed according to the illumination of the fan speed indicator You can choose the fan speed as following sequence auto hi med low auto 3 Press the or button to choose the temperature you want 4 Connected drain hose See 7 4 Drainage section 6 AIR CONDITIONER FEATU...

Страница 16: ...viously set To cancel the timer setting press the You can delay shutdown when the unit is on Press the timer button then the Timer indicator will switch on and the number of hours on the screen will show 0 0 Tap or hold the UP or the DOWN button to change delay stop timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours Press the timer button again within 5 seconds yo...

Страница 17: ...vironment Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries Do not dispose of batteries in fire Batteries may explode or leak If the remote control is not used for a long time remove the batteries from the remote control The remote control must be handled with extreme care Do not drop it or expose it to direct sunlight or sources of ...

Страница 18: ...n displays dry At the same time the low fan symbol appears on the screen Note In this mode fan speed cannot be selected Press the mode button until the left side of LCD screen displays heat Press the fan speed button to choose the fan speed auto high mid and low Press the and button to choose the temperature you want Press the mode button until the upper side of LCD screen displays auto Under AUTO...

Страница 19: ...can also press the timer button again directly and the on will stop flashing immediately then the unit will start up in the mode as previously set You can set up the mode and the unit will start up as you preferred after on stop flashing To cancel the setting press the timer button again When the unit is in Cool Heat or auto mode you can press the sleep button to make the unit run in Sleep mode In...

Страница 20: ... to 10 hours then at 1 hour increments up to 24 hours After 3 seconds the setting will be memorized and the display will show the time remaining until the unit shuts down You can also press the timer button again directly and the off will stop flashing immediately To cancel the setting press the timer button again If the display reads AS CS and ES the temperature sensor has failed Contact your Aut...

Страница 21: ...ap to the bottom drain outlet when no condensate flows out 8 CARE CLEANING Clean your air conditioner occasionally to keep it looking new Be sure to unplug the unit before cleaning to prevent shock or fire hazards The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Never use harsh cleaners wax ...

Страница 22: ... this appliance Air conditioner will not operate Air from unit does not feel cold enough Air conditioner cooling but room is too warm Wall plug disconnected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Control is OFF Turn Control ON and set to desired setting Fault code P1 appears in the display window Drai...

Страница 23: ...tting Air directional louvres positioned improperly Position louvres for better air distribution Front of unit is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registers etc open cool air escapes Close doors windows registers etc 10 ENVIRONMENTAL CONCERNS Recycle the materials with the symbol Put the packaging in applicable containe...

Страница 24: ... service without special equipment and subject to these terms and conditions repair or replace any parts which it considers to be defective Electrolux may in its absolute discretion choose whether the remedy offered for a valid warranty claim is repair or replacement Electrolux or its ASC may use refurbished parts to repair your Appliance You agree that any replaced Appliances or parts become the ...

Страница 25: ...www electrolux com shop Andes_ANZ_June_01 ...