Permanent Connection

In the case of a permanent connection, it is necessary

that you install a double pole switch between the hob

and the electricity supply (mains), with a minimum gap

of 3 mm. between the switch contacts and of a type

suitable for the required load in compliance with the current

electric regulations.
The switch must not break the yellow and green earth

cable at any point.

Ensure that the hob supply cord does not

come  into  contact  with  surfaces  with

temperatures higher than 50 deg. C.

FO 0390

F

Electrical connections

Any  electrical  work  required  to  install  this  hob

should be carried out by a qualified electrician or

competent person, in accordance with the current

regulations.

THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these

safety measures not be observed.

This hob is designed to be connected to a 230-240V

50Hz AC electrical supply.

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the hob rating

plate. The rating plate is located on the bottom of the

hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord

incorporating a 3amp plug fitted. In the event of having to

change the fuse, a 3amp ASTA approved (BS 1362) fuse

must be used.
Should the plug need to be replaced for any reason, the

wires in the mains lead are coloured in accordance with

the following code:
Green and Yellow - Earth
Blue

- Neutral

Brown

- Live

— Connect the green and yellow (earth) wire to

the terminal in the plug which is marked with
the letter 'E' or the earth symbol   or coloured

green and yellow.

— Connect the blue (neutral) wire to the terminal

in the plug which is marked with the letter 'N' or

coloured black.

— Connect the brown (live) wire to the terminal in

the plug which is marked with the letter 'L' or

coloured red.

Upon completion there must be no cut, or stray strands

of wire present and the cord clamp must be secure over

the outer sheath.

A cut off plug inserted into a 13 amp socket is a

seriuos safety (shock) hazard. Ensure that the cut

off plug is disposed of safely.

FO 0199

a

Fitting the Hob into the worktop

Carry out the building in of the hob as follows:

• put the seals supplied with the hob, on the

edges of the cut out: place them exactly on

the front and rear edge and at 50 mm. from the

side edges, taking care that the seals meet

without overlapping;

• place the hob in the cut out, taking care that it

is centred;

• fix the hob with the relevant fixing clamps and

screws, as shown in the diagram. When the

screws have been tightened, the excess seal

can be removed.

The edge of the hob forms a double seal which prevents

the ingress of liquids.

Seal

F

Содержание EPGH

Страница 1: ...EPGH GB Gas hobs INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance 35674 8901 ...

Страница 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Страница 3: ...5 Service and Spare Parts 6 Guarantee Conditions 6 Engineers technical data 9 Installation 10 Building In 11 Electrical connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 1 Hob Top 2 RapidBurner 3 Semi rapid Burners 4 AuxiliaryBurner 5 Controlknobs 6 Ignitionpushbutton 3 2 4 5 6 3 Description of the Hob 1 ...

Страница 4: ...ISCONNECT the hob from the electricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool The Hob Top Regularly wipe over the hob top using a soft cloth well wrungoutinwarmwatertowhichalittlewashingupliquid has been added Avoid the use of the following household detergent and bleaches impregnated pads unsuitable for non stick sa...

Страница 5: ... Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Service and Spare Parts When you contact the Service Centre they will need the following information 1 Your name address and post c...

Страница 6: ...liance which is improperly installed or calls to appliance outside the United Kingdom Appliances found to be in use within a commercial or similar environment plus those which are the subject of rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to another country within Europe then your guarantee moves with you to your n...

Страница 7: ...an Ridge Road Sheffield S9 1GB NORTH WEST BIRKENHEAD 1 Kelvin Park M11 Dock Road Birkenhead L41 1LT CARLISLE Unit 7 M10 James Street Workshops James Street Carlisle Cumbria CA2 5AH ISLE OF MAN South Quay Ind M64 Estate Douglas Isle of Man IM1 5AT LIVERPOOL Unit 1 M15 Honeys Green Precinct Honeys Green Lane Liverpool L12 9JH MANCHESTER Unit B M09 Central Industrial Estate St Marks Street Bolton BL3...

Страница 8: ...eld London EN3 7BB GRAVESEND Unit B4 M57 Imperial Business Estate Gravesend Kent DA11 0DL HARPENDEN Unit 4 M46 Riverside Estate Coldharbour Lane Harpenden AL5 4UN LETCHWORTH 16 17 Woodsite Ind M50 Est Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane M76 Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road M60 Maidenhead Berkshire SL6 8BY MOLESEY 10 Island Farm M61 Avenue West Mo...

Страница 9: ...p Fixed Rear Left Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Left Burner rapid Heat Input 3 0 kW 10236 BTU HR Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Aerationadjustmentnone NATURAL GAS 20 mbar TYPE OF GAS Characteristics LPG GAS 28 30 37 mbar 1 100 mm 1 100 mm VALUE 49 92 MJ Kg VALUE 37 78 MJ m 3 Ws 50 7 MJ m 3 Rear Right Burner semi rapid Heat Input 2 0 kW 6...

Страница 10: ...ir vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above the ...

Страница 11: ...allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Connectio...

Страница 12: ... fuse a 3ampASTAapproved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neut...

Страница 13: ...ss than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal eviden...

Страница 14: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Страница 15: ...ssure reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies F F Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method Ensure that the gas taps are in the ...

Страница 16: ...CUSTOMER CARE 55 77 High Street Slough Berkshire SL1 1DZ Tel 08705 950950 Electrolux Household Appliances Limited 2000 Grafihe MDM Forlì ...

Отзывы: