background image

Installation Instructions

Electrolux Front-Load Gas & Electric Dryer

Instructions d’installation

Sécheuse à gaz et à l’électricité à chargement frontal Electrolux

Instrucciones de Instalación

Secadora eléctrica y a gas de carga frontal Electrolux

137382100 A (1106)

Содержание EIMED55I MB

Страница 1: ...trolux Front Load Gas Electric Dryer Instructions d installation Sécheuse à gaz et à l électricité à chargement frontal Electrolux Instrucciones de Instalación Secadora eléctrica y a gas de carga frontal Electrolux 137382100 A 1106 ...

Страница 2: ...e known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire Do not stack a dryer on top of washer already installed on pedestal Do not stack washer on top of dryer Do not stack washer on top of another washer The instructions in this manual and all other literature included with this dryer are not meant to cover every possi...

Страница 3: ...ire 240 volt cord kit electric dryer 4 in 10 2 cm clamp Tools and materials needed for installation Installation Checklist 240v Electric Supply Electric Dryer Approved NEMA 10 30R or 14 30R service cord with all screws tight on terminal block Approved strain relief installed Terminal access cover installed before initial operation Door Reversal Follow detailed instructions in this guide Test hinge...

Страница 4: ...h upturned ends or closed loop connectors and marked for use with clothes dryers For 3 wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3 WIRE SYSTEM 4 WIRE POWER SUPPLY CORD KIT not supplied The dryer MUST employ a 4 conductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug connectors with upturned ends or cl...

Страница 5: ...of your dryer Gas supply requirements WARNING EXPLOSION HAZARD Uncoated copper tubing will corrode when subjected to natural gas causing gas leaks Use ONLY black iron stainless steel or plastic coated brass piping for gas supply 1 Installation MUST conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 latest edition 2 The gas supply line should be 1 ...

Страница 6: ...nts continued Number of 90 turns MAXIMUM LENGTH of 4 102mm Rigid Metal Duct VENT HOOD TYPE Preferred 4 10 2cm louvered 2 5 6 35cm 0 125 ft 38 10m 110 ft 33 53m 1 115 ft 35 05m 100 ft 30 48m 2 105 ft 32 00m 90 ft 27 43m 3 95 ft 28 96m 80 ft 24 38m 4 85 ft 25 91m 70 ft 21 34m WARNING FIRE HAZARD Do not allow combustible materials for example clothing draperies curtains paper to come in contact with ...

Страница 7: ... system through an uninsulated area may cause condensation and faster accumulation of lint Compression or crimping of the exhaust system will cause an increase in vent restriction The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation Manufactu...

Страница 8: ...tdoors 2 No other fuel burning appliance shall be installed in the same closet as the gas dryer 3 Your dryer needs the space around it for proper ventilation DO NOT install your dryer in a closet with a solid door 4 Closet door ventilation required A minimum of 120 square inches 774 2 cm of opening equally divided at the top and bottom of the door is required Openings should be located 3 inches 7 ...

Страница 9: ...l supply on rear of unit1 gas supply pipe on rear of gas unit gas supply pipe on rear of gas unit centerline height for rear vent centerline height for rear vent 53 5 136 cm to clear open door 53 5 136 cm to clear open door 31 5 79 5 cm to front of closed door 31 5 79 5 cm to front of closed door 75 75 192 5 cm 41 0 105 cm 39 0 99 cm 27 0 68 5 cm water supply connection on rear of unit2 drain hose...

Страница 10: ...ord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 After you purchase and install a 3 wire or 4 wire power supply cord having an equipment grounding conductor and a grounding plug that matches your wiring system the plug MUST be plugged into an appropri...

Страница 11: ...ock by a path of least resistance for electrical current 2 Since your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician 3 DO NOT modify the plug provided with this ...

Страница 12: ... Internal ground GREEN screw GREEN screw Install Install UL approved UL approved strain relief here strain relief here Terminal screw Terminal screw recovery slot recovery slot Line 1 Line 1 BRASS terminal BRASS terminal Neutral Neutral SILVER terminal SILVER terminal Line 2 Line 2 BRASS terminal BRASS terminal Access cover Access cover screw screw Terminal Terminal block block Neutral Neutral cen...

Страница 13: ...RICAL SHOCK HAZARD Do not make a sharp bend or crimp wiring conductor at connections Internal ground Internal ground GREEN screw GREEN screw Install Install UL approved UL approved strain relief here strain relief here Terminal screw Terminal screw recovery slot recovery slot Line 1 Line 1 BRASS terminal BRASS terminal Neutral Neutral SILVER terminal SILVER terminal Line 2 Line 2 BRASS terminal BR...

Страница 14: ...r that is resistant to the corrosive action of liquefied gases on all pipe connections Open the shutoff valve in the gas supply line to 3 allow gas to flow through the pipe Wait a few minutes for gas to move through the gas line IMPORTANT DO NOT connect the dryer to L P gas service without converting the gas valve An L P conversion kit must be installed by a qualified gas technician WARNING EXPLOS...

Страница 15: ...aminants in the line Remove hose kit from dryer drum and inspect 4 hose couplings for proper placement of rubber washers RUBBER WASHER MUST BE PRESENT AND UNDAMAGED COLD INLET HOSE TO WASHER RUBBER WASHERS MUST BE PRESENT WATER SUPPLY REQUIREMENTS Cold water faucet MUST be installed within 42 inches 107 cm of your dryer s water inlet The faucet MUST be 3 4 inch 1 9 cm with thread ing for laundry h...

Страница 16: ...ly thread the short extension hose on to the COLD water supply and snug it by hand then tighten it another 2 3 turn with pliers Thread the Y connector to the short 7 extension hose and snug it by hand then tighten it another 2 3 turn with pliers Connect the COLD inlet hose for the washer 8 to the Y connector and snug it by hand then tighten it another 2 3 turn with pliers Connect the straight end ...

Страница 17: ...pe to seal all other joints Carefully slide the dryer to its final position 2 Adjust one or more of the legs until the dryer is resting solidly on all four legs Place a level on top of the dryer The dryer MUST be level and resting solidly on all four legs Rock alternating corners to check for stability Remove and discard door tape Plug the power cord into a grounded outlet 3 Turn on the power at t...

Страница 18: ...window will display 4 INSTAL CYCLE and show estimated time of cycle completion Press the start button The Installation Cycle will automatically per form various diagnostic routines At cycle completion the LCD window may display INSTAL PASS meaning your new dryer is properly installed and ready for use If it prompts an action such as SERVICE CORD NO GAS or call service 877 435 3287 review the insta...

Страница 19: ...ath Preparing to reverse door swing Screwdrivers with 2 square straight bit Tools needed A Removing Trim Ring 1 Open door to 90 degree angle 2 Remove and save trim plug and long course thread panhead screw 3 Close door 4 Rotate door trim approximately counter clockwise and pull ring away from door 4 Gently place door face down on flat covered work surface 3 While supporting the weight of the door ...

Страница 20: ...ve 2 short course thread panhead screws on hinge plate 2 Remove 3 short fine thread counter sunk screws in hinge side E Reattaching Hinge to Front Panel 1 Rotate the hinge and move it to the opposite opening Use the side locating pins to align the hinge and install 1 short fine thread counter sunk screw in the center hole of hinge side 2 Install the other 2 short fine thread counter sunk screws in...

Страница 21: ...y pry upward to release tab 3 Pull the indicator out and set it aside 3 Pull the hole plug out and set it aside 1 Insert flat blade screwdriver into open slot of hole plug 2 Gently pry upward to release tab F Removing Striker Plate 1 Remove 2 long course thread counter sunk screws and latch plate 2 Set the latch plate to the side for later ...

Страница 22: ...s down press down and snap and snap 3 Firmly press downward on the indicator until the tab snaps in place 2 Firmly insert the two small tabs on either side of the latch indicator into the two slots on either side of the hole in the door insert tab insert tab press down press down and snap and snap K Reinserting Hole Plug 1 Rotate the hole plug and move it to the opposite hole in the door 2 Firmly ...

Страница 23: ... Reversing Trim Ring 1 Trim ring orientation is marked on the back 2 Remove trim ring cover plate To remove plate from left pivot point is down To remove plate from right pivot point is up UP N Reinstalling Trim Ring 1 Close door 2 Orient trim so UP position is approximately to the left of top center Opening in ring should be on the hinge side 3 Insert trim ring in slots and rotate clockwise appro...

Страница 24: ... of your unit for a total height of 53 134 62 cm Other colors may be available Contact the source where you purchased your dryer DRYER STACKING KIT P N 134700400 Depending on the model you purchased a kit for stacking this dryer on top of matching washer may have been included in the initial purchase of your dryer If your model did not include a stacking kit or you desire another stacking kit you ...

Отзывы: