6.14. Service function / readout of fault memory and single actuator selection:
General information
Calling above-mentioned service function
w
Calling the service function is executed in all designs
Calling the functions
resp. key arrangements analogously.
"readout of fault memory" and "single actuator selection"
w
For that you always have to use keys S0, S1, S2 and S3
independent of their variant-depending program load.
1.
Appliance in switched-off condition
w
In the service function mode key S1 is ALWAYS
2.
Press keys S1 and S3 simultaneously and ...
responsible for the function "readout of fault memory"
3. / 4.
... and switch on the appliance by ON/OFF switch S0.
and "single actuator selection"
For that keep pressed keys S1 and S3 until the 3
confirmation LEDs LD1, LD2 and LD3 are flashing.
( A temporary flashing up of LEDs is possible and no fault!)
5. / 6.
By actuating the function key S1 you now can call the function.
The confirmation LED LD1 continues flashing, LEDs LD2 and
LD3 go out.
The first value of the fault memory is indicated in the display.
The display indication is flashing.
By any further actuation of the function key S1 it is possible
to call the next step and indicate it in the display as follows.
2. actuation: Display of second value of the fault memory
3. actuation: Display of third value of the fault memory
4. actuation: Display "4" - selection of regeneration valve
5. actuation: Display "5" - selection of drain pump
6. actuation: Display "6" - selection of valve
(filling to level - if level already existing, no filling)
7. actuation: Display "7" - selection of heating
(only when level detected)
8. actuation: Display "8" - selection of circulation pump
9. actuation: Display "9" - selection of detergent dispenser
10.actuation: Display "10" - selection of drying fan
(see description page B 19 / "Survey of fault displays")
It is generally valid:
All positions can be called scrolling as many time as one wants.
For calling all service functions you always have first to
actuate function keys S1 and S3 before switching on
The several steps are switched onward manually by pressing
the applianceby ON/OFF switch S0.
any key. If the function key S1 is not pressed within 60 seconds,
The keys have to remain pressed about 3 seconds
the service function is left automatically. All LEDs of the
to activate the function.
program and option keys are lit. The indication in the display
This procedure is intentionally different to that for the
goes out. The appliance is in the "prestart" mode again.
customer functions.
It is also possible to leave the function by switching off the
appliance by ON/OFF key S0.
EDW 1503 / VGA
LD1
LD2
LD3
S1
S3
1
99
S0
2.
S1
S3
1.
S0
LD1
LD2
LD3
LD4
LD5
LD6
S1
S2
S3
S4
S5
S6
LD10
LD11
LD12
3.
S1
S3
S0
3-4 Sekunden
5.
1 0
LD1
S1
4.
S1
S3
S0
LD1
LD2
LD3
alle blinken
Display und LED blinken
Display und LED blinken
pro Tastendruck
1 Weiterschaltung
Anzeige 2. + 3.Fehlers
Codierte Anzeigen
der Einzelaktoren
I 0
LD1
S1
I 0
4
5
10
6.
1 0
LD1
S1
Display und LED blinken
... AUS nach 60sek. automatisch
S0
S0
... AUS durch manuelle Betätigung über Ein/Aus
LD1
LD2
LD3
LD4
LD5
LD6
34