When calling the service functions no washing cycle
must be selected generally!
6.12. Customer function / deactivation of rinse-aid addition
General information
Calling / changing / saving the rinse-aid addition deactivation
The function rinse-aid deactivation does not exist generally
Calling the function "deactivate rinse-aid addition"
and must be programmed in the software variant.
1.
Appliance in switched-off condition
w
Deactivation resp. activation of rinse-aid addition is executed
2.
Switch on appliance with ON/OFF key S0 -- "prestart" mode
in all designs resp. key arrangements analogously.
Ä
All LEDs of the program and option keys are lit.
w
For that you always have to use keys S0, S1, S2 and S3
independent of their variant-depending program load.
3.
Press keys S2 and S3 simultaneously until the
w
Key S2 is ALWAYS the "rinse-aid deactivation key"
confirmation LEDs LD1, LD2 and LD3 are flashing.
w
The rinse-aid addition is always set active by the manufacturer.
w
If the rinse-aid addition is deactivated it means that no more
4.
By actuating the function key S2 you now can call the
rinse-aid is added via the detergent dispenser.
function rinse-aid addition. The confirmation LED LD2
Along with the deactivation, a variant-depending existing
continues flashing, LEDs LD1 and LD3 go out.
"rinse-aid" LED is deactivated generally.
The current condition whether the rinse-aid addition is
active or not is indicated in the display.
1d = rinse-aid addition on / 0d = rinse-aid addition off
Deactivation resp. activation of rinse-aid addition:
5. / 6.
By any further actuation of the function key S2 you activate
resp. deactivate the addition alternating.
Leaving the function
After the last key pressure of the function key S1 you can
leave the special program as follows.
After 60 seconds all LEDs of the program and option keys
are lit automatically. The indication in the display goes out.
The appliance is in the "prestart" mode again
or
the appliance is switched off by ON/OFF key S0.
Saving the set condition
The currently valid condition is saved directly after
any entry.
EDW 1503 / VGA
LD1
LD2
LD3
S2
S3
1
99
S0
1.
2.
4.
3.
... AUS nach 60sek. automatisch
S0
S0
S0
S0
... AUS durch manuelle Betätigung über Ein/Aus
LD1
LD2
LD3
LD4
LD5
LD6
S1
S2
S3
S4
S5
S6
LD10
LD11
LD12
LD1
LD2
LD3
LD4
LD5
LD6
S2
S3
blinken
LD1
LD2
LD3
1d
LD1
LD2
LD3
LD4
LD5
LD6
LD2
S2
blinkt
5.
0d
LD2
S2
blinkt
6.
1d
LD2
S2
blinkt
32