12.1
If the drying results are not
satisfactory
• The set programme was incorrect.
• The filter is clogged.
• The Heat Exchanger is clogged.
• There was too much laundry in the
appliance.
• The drum is dirty.
• Incorrect setting of the conductivity
sensor ( See chapter "
Settings -
Adjustment of the remaining laundry
moisture degree
" for better setting).
• The airflow slots are clogged.
• Room temperature is too low or too
high ( optimal room temperature 19°C
to 24°C )
13.
TECHNICAL DATA
Height x Width x Depth
850 x 600 x 540 mm (maximum 600 mm)
Max. depth with the appliance door open 1030 mm
Max. width with the appliance door open
950 mm
Adjustable height
850 mm (+ 15 mm - feet regulation)
Drum volume
104 l
Maximum load volume
7
kg
Voltage
230-240 V
Frequency
50 Hz
Total power
2800 W
Type of use
Household
Permitted ambient temperature
+ 5°C to + 35°C
Level of protection against ingress of sol‐
id particles and moisture ensured by the
protective cover, except where the low
voltage equipment has no protection
against moisture
IPX4
www.electrolux.com