ON/OFF button
6
6
Door Open alarm signalling icon
7
7
High temperature alarm signalling icon
8
8
Low temperature alarm signalling icon
9
9
Assistance alarm signalling icon
1
10
0
Defrost/Down button
1
11
1
UP/Continuous Cycle button
1
12
2
Set button
1
13
3
High/low humidity button
1
1
14
4
Programme selection button
1
15
5
History button
1
16
6
History function on signalling icon
1.
refrigerated models only
E
E
IIN
NS
ST
TR
RU
UC
CT
TIIO
ON
N F
FO
OR
R T
TH
HE
E U
US
SE
ER
R
E
E..1
1
S
Sw
wiittcch
hiin
ng
g tth
he
e a
ap
pp
plliia
an
ncce
e o
on
n
Connect the power cable to a power socket. The instrument
display performs a Lamp Test and the message OFF will
appear.
To activate and deactivate the appliance press the button
for 5 seconds.
The display will show the message ON (for activation) or OFF
(for deactivation).
Even if the machine is deactivated with the ON/OFF button it
still remains powered.
This button only disconnects the power to the loads connected
to the instrument.
E
E..2
2
C
Co
on
nttrro
oll p
pa
an
ne
ell b
bu
utttto
on
nss
• H
Hu
um
miid
diittyy b
bu
utttto
on
n
Present only on refrigerated models, it is used to set 3
different humidity levels.
Humidity varies on the base of the ambient temperature and
the cell temperature (Set point).
Depending on the humidity level, the display will show the
images with:
– 1 line (low humidity - from 40% to 50%)
– 2 lines (medium humidity - from 60% to 70%)
– 3 lines (high humidity - from 70% to 85%)
Use the buttons
to select the most suitable humidity
level.
T
Ta
ab
blle
e o
off cca
atte
eg
go
orriie
ess,, cco
om
mp
pa
arrttm
me
en
ntt tte
em
mp
pe
erra
attu
urre
e a
an
nd
d
h
hu
um
miid
diittyy sse
ettttiin
ng
g
C
Ca
atte
eg
go
orriie
ess
T
Te
em
mp
pe
erra
attu
urre
e
((℃
℃))
H
Hu
um
miid
diittyy
Fresh meat (beef,
mutton, pork)
4
high humidity
Poultry
-2
high humidity
Fruit & Vegetables
6
high humidity
Eggs, Butter,
Cheese, Charcuterie
6
high humidity
Fresh fish
4
high humidity
Patisserie
6
high humidity
Beverages
8
medium
humidity
To confirm the degree of humidity selected, press the button
for 5 seconds.
• U
Up
p--D
Do
ow
wn
n b
bu
utttto
on
nss
Up for increasing the values;
Down for decreasing the values;
• C
Co
on
nttiin
nu
uo
ou
uss ccyycclle
e b
bu
utttto
on
n
Press the button
more than 5 seconds to activate the
Turbo Cooling “TC“ cycle function (the message ccb=start
appears);
the temperature reinstatement function is activated, skip-
ping Defrost.
During the continuous cycle the compressor remains on;
the low temperature alarm is deactivated;
the message TC and the temperature value alternate on the
display.
The continuous cycle ends:
– when the button is pressed (the message cce=end
appears);
– when the minimum foreseen temperature is reached;
– when the maximum duration (time 1h) is reached;
– when the instrument is switched off.
• S
Se
ett b
bu
utttto
on
n
.
Press for more than 1 second to display and/or set the
sse
ettp
po
oiin
ntt. To increase or decrease the values use the
buttons
. To confirm the new value, press the Set
button
.
• D
De
effrro
osstt b
bu
utttto
on
n
IIM
MP
PO
OR
RT
TA
AN
NT
T
Do not use mechanical devices or other
means to speed up the defrost process,
unless
recommended
by
the
manufacturer.
Do not damage the circuit.
The appliance has an automatic defrost function. A manual
defrost cycle can be started by keeping the button pressed
for at least 5 seconds (the display shows the message dFb ).
This function is signalled by lighting up of the defrost icon
. Defrost is with forced ventilation only for refrigerated
models with compartment set point higher than or equal to
“+2“.
Defrost can be stopped manually by pressing the button for
a few seconds (the display shows the message dFE).
Defrost cannot be activated in the continuous cycle
programming phase. If the continuous cycle is activated
and the button is pressed, defrost will be carried out at the
end.
• P
Prro
og
grra
am
mm
me
e sse
elle
eccttiio
on
n b
bu
utttto
on
n
It is used in the HISTORY function (see the following
paragraph). Pressing this button also brings up the
Technical Menu, which cannot be modified.
• H
Hiisstto
orryy b
bu
utttto
on
n
Records the temperature every 24 hours from activation, for
a total of 62 saves.
Records high/low temperature alarms. The first press of the
button
brings up the list of daily recorded values (t00=
current day; t01, t02, t03, etc.=recording days going back).