Страница 2: ...iler 8 Descale Air O Steam Touch Control Boiler 7 Programmed Maintenance Rotating Jet 6 Oven Cavity Descale All Models 6 Chamber Lamp Replacement 6 Inspection 6 Monthly Cleaning Touch Control Dial Control Drip Tray 5 Fan Element Compartment 5 Door Cavity 5 Air Filter if fitted 5 Daily Cleaning Touch Control Touch Control Step 1 3 Touch Control Step 2 3 Touch Control Step 3 3 Information Cleaning a...

Страница 3: ...e cleaning or maintenance Never use water to cool the unit Boiler descale is for Air O Steam Models It should be performed as frequently as required and at least every 6 months Water filtration is critical Filter cartridges MUST be replaced periodically Failure to do so will void your warranty Frequency will depend on your water quality and type of filtration system see page 9 Ensure temperature p...

Страница 4: ...Reduce water consumption Skip drying Skip rinse aid Green Spirit Soft 0 45 1 00 1 30 2 30 Medium Strong Extra Strong To Enter the Cleaning modes press the Manual tab on the main screen Select Cleaning from the drop down menu Select the required cleaning cycle from the Cleaning menu By default the oven is set to Medium Assess how soiled the oven is then select the appropriate wash cycle If desired ...

Страница 5: ... onto soiled areas Close the oven door Allow 10 15 minutes for oven cleaner to dissolve soil Run appropriate cleaning cycle This must be done to wash and remove all oven cleaner residue from the oven Dial Control Step 3 1 2 3 To Enter the Cleaning modes press the Utilities button then with the dial select the Cleaning Mode Press the Utilities button again Assess how soiled the oven is then select ...

Страница 6: ...age Remove any loose soil from the Fan Element compartment Wipe clean using a clean damp cloth For hard to remove soil spray undiluted oven cleaner onto soiled areas Close the Fan Element compartment Allow 10 15 minutes for oven cleaner to dissolve soil Run appropriate cleaning cycle to ensure all oven cleaner is removed from the oven Door Cavity 2 1 Press the two clips to release the hinged glass...

Страница 7: ...ld up is present or rotating arm does not move freely remove for cleaning Using a flat head screw driver extract without removing the retaining clip A from the middle block of the rotating arm Remove the rotating arm from the from the rotation pin If the nozzles are completely obstructed use a small screwdriver or blade to remove any scale build up Submerge the rotating arm in a container of pure ...

Страница 8: ...ack rubber stopper on the top left hand side of the oven DO NOT DISCARD Using a funnel slowly pour in the required volume of pure white vinegar as per the chart below until the buzzer sounds continue pouring the remaining measured volume of vinegar Required volume of vinegar in Litres 6 Replace the black rubber stopper the display will indicate a time of 2hrs 50 minutes 7 For the last 20 minutes t...

Страница 9: ...boiler drain button to drain the vinegar Leave the drain valve open 7 Turn on the water supply to oven and wait 20 seconds allowing the water to flush the boiler Press the boiler drain button to close valve The led light will blink indicating the valve is closing When there is an excessive build up of scale in the steam generator the icon will turn on signalling the need to carry out de scaling ev...

Страница 10: ... creating error messages Reverse Osmosis Filter Cartridges A reverse osmosis filter is required in areas where the water has high chlorides or other corrosive minerals present Where appropriate this system should have been recommended by your supplier at the time of your oven purchase Filters 1 2 and 3 to be changed a minimum of every 6 months or more frequently in areas with poor water quality Fi...

Страница 11: ...errupted or short circuited EPt2 Boiler sensor interrupted or short circuited EPt3 Probe sensor interrupted or short circuited EPt4 Bypass sensor interrupted or short circuited EPt8 Electronic controller temperature sensor damaged ESCH Malfunction of commands control circuit cooling devices Etub Boiler over temperature 125 C warning Etuc Chamber over temperature 320 C warning EFLP Fault in chamber...

Страница 12: ... F5300N00A00 SPAR XSE AX10 CCF SPAR XSE AX10 GAC SPAR XSE AX10 ROM OC9877 OC2626 Professional Oven Cleaner 2 x 5 Litre Professional Oven Rinse Aid 2 x 5 Litre BWT Best Protect 2XL Filter Cartridge No 1 Sediment and Dirt Particles Removal Cartridge RO Unit No 2 Chlorine Taste Odour Reduction Cartridge RO Unit No 3 Reverse Osmosis Membrane Cartridge RO Unit Oven Chamber Light Bulb 12v 10w 300 C Oven...