“L1,L2,L3
”
to the residual leakage circuit-breaker
(G) which should be supplied by the customer.
Connect the PE to the customer's grounding
terminal.
Power supply 220-240V 1P+N
Figure 12 220-240V 1P+N
Connect the power supply as shown in Figure 12:
Use the supplied power supply cables
(
I) (refer to
technical data sheet). Connect the 1-phase cable
“L1,N
”
to the residual leakage circuit-breaker (G)
which should be supplied by the customer.
Connect the PE to the customer's grounding
terminal.
E8 Safety Devices
•
The
automatically
resettable
thermal
protective device that is incorporated into the
winding of the electric pump may cut off the
power supply in case of fault.
•
In case of faulty main water supply pipe, a
device is used to prevent the boiler water
from being returned into the main pipe.
•
Level balance: When the level is higher than
the standard value, the drain pump
discharges water so that the tank level is
kept constant.