• When removing the anchoring systems, make sure the stability of the appliance parts
does not depend on the anchoring and, therefore, that this operation does not cause the
load to fall off the vehicle. Before unloading the appliance components, make sure all
the anchoring systems are removed.
A.10
Installation and assembly
• The operations described must be carried out in compliance with the current safety
regulations and provisions in force in the country of use.
• The plug, if present, must be accessible after positioning the appliance in the place of
installation.
• The appliance is not suitable for installation outdoors and/or in places exposed to
atmospheric agents (rain, direct sunlight, etc.).
A.11
Electrical connection
• The electric supply connection must meet all national and local electrical code
requirements.
• The power supply system must be suitable for the rated current of the connected
appliance.
• The information regarding the appliance power supply voltage and frequency is given on
the data plate.
• Install between the power cable and the electric line a differential thermal-magnetic
switch suitable for the absorption specified on the data plate, with contact gap enabling
complete disconnection in category III overvoltage conditions and complying with the
regulations in force.
For the correct sizing of the switch or plug, refer to the absorbed current specified on the
appliance data plate.
• If the power cable is damaged or too short, it must be replaced by the Customer Care
Service or in any case by specialised personnel, in order to prevent any risk.
• The manufacturer declines any liability for damage or injury resulting from breach of the
above rules or non-compliance with the electrical safety regulations in force in the
country where the appliance is used.
• Verify that a safety circuit breaker is installed between the power cable of the appliance
and the mains electric line. The contact opening max. distance and leakage current
must comply with the local safety regulations.
• In case of electrical permanent connection: the device must be lockable in the open
position and accessible even after the appliance is installed in its place.
A.12
Water connection
Water connection must be carried out in compliance with the regulations and
provisions in force with the country.
• The appliance must be supplied with drinking water at a pressure of 1,5 – 3 bar (150 –
300 kPa).
WARNING
The manufacturer declines any liability if the safety regulations are not
respected.
A.13
Positioning
• Install the appliances, taking all the safety precautions required for this type of operation,
also respecting the relevant fire-prevention measures.