Installation manual
17
7.2.1
Machine with connectors
Connect the external dosing system to connections A and B on the machine.
Connect the signal cable to B and the power supply to A.
For Efficient dosing system the cables are delivered with the machine.
Connect the power supply cable to the machine A and the other end of the cable together with the cable from Effi-
cient Dosing in a connection box or with plug and receptacle.
Connect one end of the cable to the Efficient Dosing Controller J2 and the other end to the machine B.
Connection box
B
1
2
3
4
1
2
3
4
5
7
6
9
J1 RJ11 J2
Controller
Pump unit
A
fig.6598B
A
B
1
Line
1
2
Neutral
2
3
3
Gnd
4
Ground
4
5
6
7
8
Rx
9
Tx
Signal 1–5 are used in the Efficient dosing controller.
6W02
6G01
Signal 1
Detergent Lagoon
-
Signal 2
-
Detergent Main wash
Signal 3
Conditioner Lagoon
-
Signal 4
All in one Lagoon
-
Signal 5
-
Bleach Main wash