background image

Installation manual

Jetsave Dosing System

For washer extractors L6000 with Clarus Vibe

Original instructions

438917541/EN

2022.10.04

Содержание Jetsave

Страница 1: ...Installation manual Jetsave Dosing System For washer extractors L6000 with Clarus Vibe Original instructions 438917541 EN 2022 10 04 ...

Страница 2: ......

Страница 3: ...Pairing the pumps Addressing the I O board 18 5 5 Priming the pumps 20 5 6 Calibrating the pumps 20 5 7 Installation of low level probe option 21 5 8 Connection with low level sensors probes 21 6 Technical specification 23 7 Trouble shooting and service 23 8 Disposal information 24 8 1 Disposal of appliance at end of life 24 8 2 Disposal of packing 24 The manufacturer reserves the right to make ch...

Страница 4: ......

Страница 5: ... appliance is not be used by persons including children with re duced physical sensory or mental capabilities or lack of experience and knowl edge unless they have been given supervision or instruction This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given superv...

Страница 6: ...intended for connection to an external conductor for protection against electric shock in case of a fault or the terminal of a protective earth ground electrode Refer to product manual Read the instructions before using the machine Protective Personal Equipment The use of appropriate eyewear shall be used Protective Personal Equipment The use of appropriate safety gloves shall be used Protective P...

Страница 7: ...ed within 3 m from the washer extractor with possibility to extend the dis tance up to 15 m using optional power and the data cable and close to product containers and at a convenient height for servicing about 1 1 5 m The input tubing from the chemical container to the Jetsave shall not be more than 2 m The tubes must not be twisted and shall hang freely without any sharp bends Longer tubes requi...

Страница 8: ...ycling instruction for packaging 1 1 1 2 3 3 4 2 fig X02421 Fig Description Code Type 1 Plastic bag LDPE 4 Plastics 2 Cable Ties Other Plastics Nylon 3 Cling film LDPE 4 Plastics 4 Cardboard packaging PAP 20 Corrugated card board ...

Страница 9: ... wall mounting bracket with the screws Make sure the wall mounting brackets are in level Mount the electrical box on the wall bracket and secure with the clips There are different sizes of the Jetsave system unit for 2 3 4 5 6 8 and 10 pumps Product 2 6 pumps Product 8 10 pumps For 2 6 pumps products drill the holes for the pump units according to the following figure 132 4 mm 158 9 mm fig X02401 ...

Страница 10: ...g button D Data in E Power in from washer extractor 230V 50 60Hz 0 1A Max F Power out G Pump power connection H Earth connection J Pairing button No 1 1st I O board K Pairing button No 2 2nd I O board Cable glands Connection of low level sensor inputs low level alarm ports The pairing button on the underside of the Jetsave control unit is used to pair the device to the washing machine ...

Страница 11: ...ust be min 26 psi 1 8 bar and max 90 psi 6 bar The one way valve C must be installed to the main water pipe or at the tap to avoid risk of breaking at inlet A The hose D and adapter E are not included in the kit They can be ordered as accessories or any extra required adapters which are field supplied can be used Connect the water outlet B to the washer extractor using the hose Secure the hose to ...

Страница 12: ...o the check valve while connected to the manifold D FL 1 2 3 4 fig X02362 Warning Do not connect any chemical hose to the FL flush position Cut the hose to the length needed Push the hose E on to the check valve D and secure with a cable tie Connect the elbow F to the manifold and secure with the white clip G F G 2 3 D E 1 fig X01357 ...

Страница 13: ...hole shall be 20 mm 3 4 Use cable tie to fasten the suction pipe under the lids to prevent the suction pipes of floating or moving up from the containers NOTE Do not drill the hole when the lid is fastened to the chemical container Fasten each lid to the chemical containers again and insert the inlet tubes in the holes fig X01321B ...

Страница 14: ... the right side of the Jetsave pumps unit to the connection to be used on the washer extractor Mount the rubber adapter rubber bushing clamps hose from pumps unit to the connection A according to the following figure Tighten clamps B with torque 3 Nm 2 2 lbf ft A B fig X02360 If the hoses are made of a soft material such as silicone or similar make sure the hose size isn t reduced isn t sharp bend...

Страница 15: ...a out connection on the Jetsave control unit 1 B 1 fig X01168F Note The termination resistor isn t needed for Jetsave 6 10 pumps products Save the termination resistor for future use If the dosing system is uninstalled from the machine the termination re sistor must be remounted on its position on the machine Connect the cables from the Jetsave control unit 1 to connections A power out and B data ...

Страница 16: ...termination resistor is already connected to an existing Jetsave control unit the connector with termination resistor shall be moved from the first Jetsave control unitand connected to the last Jetsave control unit fig X01168_5 Connect the cables from the second Jetsave control unit to the connections on the first Jetsave control unit or if three Jetsave systems are used from the third Jetsave con...

Страница 17: ...rgent 5 W1 sensitive detergent Pump 7 W02 delicate detergent 6 W2 delicate detergent Pump 8 W03 sensitive conditioner 7 W3 sensitive conditioner Pump 9 Detergent 2 8 Detergent 2 Pump 10 Bleach 2 9 Bleach 2 Pump 11 Floor care 2 10 Floor care 2 Pump 12 Floor care 3 11 Floor care 3 Pump 13 Preservation 12 Preservation Pump 14 Impregnation 13 Impregnation Pump 15 Descaling 14 Descaling Pump 16 Sour 15...

Страница 18: ... O board Enter the Advance manager password or Advance service password to access the Main menu Activate the Settings menu Activate the I O board addressing menu Available I O boards and addresses will now be visible on the screen as a drop down list The different I O boards and addresses are marked with either a green or a grey light Green light in use Grey light not in use and available for addr...

Страница 19: ... 2 5 pumps products Press the pairing button C on the Jetsave control unit For 6 10 pumps products Pairing button No 1 J will be for 1st I O board and Pairing button No 2 K will be for 2nd I O board Product 2 5 pumps Product 6 10 pumps C K J A green light on the second row for I O Type 22 indicates that the pairing has been successfully done fig X02322 ...

Страница 20: ...he pumps 5 6 Calibrating the pumps Enter the Advance manager password or Advance service password to access the Main menu Activate the Pumps menu Activate the Calibration menu Activate P1 from the list to start calibrating the first pump The different steps to be made when calibrating will now be visible on the screen 1 Fill a container with ml markings minimum volume 350 ml with the product to be...

Страница 21: ...emove the cross head screw securing the float magnet remove the float magnet and refit it in the opposite direction A C B fig 8052D 5 8 Connection with low level sensors probes Open the Jetsave control unit before connection If low level sensors are installed an error message will be displayed when any of the chemical tanks are low The program will however continue As the A122 board is with 5 outp...

Страница 22: ...an be extended for dosing up to 15 chemicals by using three JETSAVE units Tank 4 Tank 7 Tank 14 Tank 11 Tank 9 Tank 10 Tank 8 Tank 15 Tank 12 Tank 13 Tank 5 Tank 6 Low level alarms 24V OV Low level alarms OV 24V JETSAVE 2 A122 JETSAVE 3 A122 6 7 8 3 4 5 4 5 6 7 6 7 8 3 4 5 1 2 1 2 8 9 10 11 12 13 14 15 fig X01528E Available inputs on A122 for low level sensing The first JETSAVE in the loop 5 7 inp...

Страница 23: ...n 1 8 bar Max 6 bar This unit complies with the following directives and standards 2014 35 EU Low Voltage Directive LVD 2014 30 EU Electromagnetic Compatibility EMC EN 61000 6 2 EN 61000 6 4 2001 EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 7 Trouble shooting and service Trouble shooting may only be carried out by qualified service personnel Isolate the power and the water before carrying out any m...

Страница 24: ...cycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recy cling of this product contact the local dealer o...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...