Installation manual
21
6 Water connection
All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal-
lation and servicing.
Water pipes and hoses should be flushed clean before installation.
The machine shall be connected with new water hoses. Re-used water hoses must not be used.
Hoses are to be of an approved type and grade and comply with IEC 61770.
After installation hoses must hang in gentle arcs.
All connectors present on the machine must be connected. The table shows the possible connection options, which
will depend on the water types to be connected to the machine. Information is also available on the panel above the
connections.
Water type
Water connection
1
2
WH6–7, WH6–8
• Cold and hot
WH6–7, WH6–8
1. Cold
2. Hot
1
2
3
WH6–14, WH6–20, WH6–27, WH6–33
• Cold and hot
WH6–14, WH6–20, WH6–27, WH6–33
1. Cold
2. Hot
3. Cold (for detergent container) / Hot
There is also an extra water valve which can be used for hard water if soft water is connected to 1.
This valve can also be used for water re-use from tank.
If pump is used, it is only a water connection without valve.
For WRAS-approved machines: Remove the three plastic covers (A).