Electroline DROPAmp EDA-FT Series Скачать руководство пользователя страница 1

 

305-0076 Ver.1 Copyright © 2001-2003  Electroline Equipment Inc., 8265 St-Michel Blvd.

Montréal, Québec H1Z 3E4 

 

Tel. 800-461-3344 or (514) 374-6335   Fax (514) 374-2257   [email protected] 

.

 

                     

 

                    

DROP

Amp

TM

             

                     

Installation Instructions

 

Important Safety Instructions 

Read these instructions. Keep these instructions. Heed all warnings. Do 

not use this apparatus near water. Clean only with a dry cloth. Only use 

attachments/accessories specified by the manufacturer. Unplug this 

apparatus during lightning storms or when unused for long periods of 

time. Refer all servicing to qualified service personnel. Servicing is 

required when the apparatus has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid has been spilled or objects 

have fallen into the apparatus, the apparatus has been exposed to rain or 

moisture, does not operate normally, or has been dropped. 

WARNING:

 To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. 

The above instructions and warning apply only to the wall adapter.

 

 

Materials supplied

 

• 

Electroline 

DROP

Amp EDA-FT, EDA or ERA series 

• 

Wall adapter, 120 VAC, 15 VDC (or 120 VAC, 18 VDC for 

two-way or return path models) 

• 

Electroline Power Inserter model EDA-IC-F (optional)

 

Materials not supplied

 

• 

1” screws (#6) of an appropriate type for the mounting surface 

• 

nylon screw anchors (

3

/

16

” x 1”)  

• 

coaxial cables with male F-type connectors 

• 

grounding wire (#6–#14 gauge) 

Installation

 

1.  With two 1” #6 screws, mount the 

DROP

Amp on a wood, drywall, 

brick or cement surface. Use nylon screw anchors on all mounting 

surfaces other than wood.  

2.  To ground the 

DROP

Amp, insert #6–#14 gauge grounding wire in the 

hole at the top left edge of the 

DROP

Amp. Tighten the seizure screw 

with a #2 Phillips head screwdriver. 

3.  Connect the CATV drop cable to the 

DROP

Amp’s 

RF IN

 connector. 

4.  Follow the Local Powering (A) or Remote Powering (B) instructions. 

A.   For Local Powering 

A1.  Connect the subscriber’s TV set(s) or cable converter(s) to the 

output(s) on the 

DROP

Amp. Note that the ERA 4100 is 

normally used to connect a cable modem or interactive set-top 

box. Install 75-ohm terminators on any unused outputs. 

A2.  Use coaxial cable with a male F-type connector at each end to 

connect the wall adapter to the 

DROP

Amp’s 

PWR

 connector. 

The wall adapter’s F connector should be hand-tightened only. 

The maximum recommended length for the cable is 100 feet 

(30 meters), or 57 feet (17 meters) for the ERA 4100 model. 

Figure A: Example of Local Powering 

 

TM

EDA 2400

PWR    15 VDC  270 mA

5 - 42 54 - 1000 MHz   6 kV

Wall outlet power

adapter

*Unplug in order
to reset.

Insert ground wire

To TVs or cable

converters

CATV signal

input

Mounting

hole

Mounting

hole

Hand-tighten

only

OUT2

+7dB

OUT3

+7dB

OUT4

+7dB

OUT1+PWR

+7dB

 

Insert ground wire

To TVs or cable

converters

CATV signal input

Mounting

hole

RF OUTPUTS

TM

PWR 15 VDC

EDA-FT08000

5 - 42    5 4 -1000  MHz  6 kV

PWR

RF IN

PWR

REV    LOSS   10 dB

FWD   GAIN     3 dB

PWR

LED

REMOTE

(TOP)

Wall outlet power

adapter

*

Unplug in order

to reset.

Hand-tighten

only

Mounting

hole

 

Troubleshooting:

  

If the 

DROP

Amp is not working (power LED is off or dim, or output 

signal is not amplified), check for a short circuit on the coaxial cable 

between the 

DROP

Amp and the wall adapter. 

Repair the short circuit

and then reset the wall adapter as follows: 

• 

Unplug the wall adapter from the power source, and wait 20 seconds. 

This resets the overload protection device (PTC), where applicable. 

 

• 

Plug the wall adapter back into the power source. The 

DROP

Amp’s 

green power LED should now be lit brightly. If the LED is dim, 

repeat the reset procedure. If problems persist, contact 

Electroline’s technical support department.

 

B.   For Remote Powering

 

B1.  With one 1” #6 screw, mount the Power Inserter on a wood,

drywall, brick or cement surface.  Use a nylon screw anchor on

all mounting surfaces other than wood. 

B2.  Run a coaxial cable from the 

RF TV

 connector on the Power

Inserter to the subscriber’s TV set or cable converter. Note that

the ERA 4100 model is normally connected to a cable modem or

interactive set-top box. 

B3.  Connect one end of the subscriber’s additional TV sets or cable

converters to the remaining outputs on the 

DROP

Amp. Install

75-ohm terminators on any unused outputs. On all models, do not

connect anything to the 

PWR

 port.  

B4.  Use coaxial cable with male F-type connectors at each end to

connect the Power Inserter’s 

RF

-

PWR TO AMP

 connector to the

DROP

Amp’s remote power output (

REMOTE PWR

 or

 OUT

1

).  

B5.  Use coaxial cable with male F-type connectors at each end to

connect the wall adapter to the Power Inserter’s 

PWR IN

connector. The wall adapter’s F connector should be hand-

tightened only. The maximum recommended length for the

coaxial cables from the wall outlet to the 

DROP

Amp is 100 feet

(30 meters), or 21 feet (6 meters) for the ERA 4100 model. 

5.  Plug the wall adapter into an indoor power outlet. If properly

connected, the 

DROP

Amp’s green power LED will be lit.  

Figure B: Example of Remote Powering 

 

RF TV

5-1000

MHz

RF-PWR

TO

AMP

PWR

IN

TM

OUT1+PWR

+7dB

OUT2

+7dB

OUT3

+7dB

OUT4

+7dB

Power Inserter

CATV signal

input

Mounting

hole

Mounting

hole

Wall outlet

power adapter
*

Unplug in order

to reset.

To TV or cable

converter

Insert ground wire

DO NOT

CONNECT

Hand-tighten only

To TVs or cable converters

EDA 2400

PWR    15 VDC  270 mA

5 - 42 54 - 1000 MHz  6 kV

 

Insert ground wire

CATV signal input

Mounting

hole

RF OUTPUTS

TM

PWR 15 VDC

EDA-FT08000

5 - 42   5 4 -1000 MHz 6 kV

PWR

RF IN

PWR

REV    LOSS   10 dB

FWD   GAIN     3 dB

PWR

LED

REMOTE

(TOP)

Wall outlet power

adapter
*

Unplug in order

to reset.

Hand-

tighten

only

Power Inserter

To TV or cable

converter

RF TV

5-1000

MHz

RF-PWR

TO

AMP

PWR

IN

DO NOT

CONNECT

Mounting

hole

To TVs or cable

converters

 

 

For warranty, repair or return information, visit our Web site at 

www.electroline.com

 

 

 

EDA-FT Series 

EDA and ERA Series 

EDA-FT Series 

EDA and ERA Series 

Отзывы: