Set the Modbus 16 Bit Unsigned Integer, 32 Bit or 2 X 16 Bit Floating Point Mode
UuuIFxxxx
uu = unit number
xxxx = 1007 will set the 16 bit Unsigned integer mode. This is the default setting.
xxxx = 1008 will set the 32 bit floating point mode.
xxxx = 1009 will set the 2x16 bit floating point mode (v3.14 and higher).
Response: UuuIFOK
Force Sensor to Enter Boot Load Mode (Version 3.15 and Higher, (Future Use)
U
UU
FB
uu = two-digit unit number
Response: none
Enter High Level Electronic Shut Down (ESD Mode) (Version 3.15 and Higher)
UuuESDONn
uu = unit number
n = one-digit number from 1 to 3 which represents the number of level request
commands that will respond with the maximum level without cycling power. After this
number, the sensor reverts to normal operation
Note: If power is cycled, then the count reverts back to the programmed number of
polls.
Response: UuuESDONOK
ESD mode was successfully activated
Exit High Level Electronic Shut Down (ESD Mode) (Version 3.15 and Higher)
UuuESDOFF
Response: UuuESDOFFOK ESD mode exit successfully
Note: UuuESDON0 also turns off ESD mode