© ElectroCraft 2022
19
CPP-A12V80A-SA-CAN Drive User Manual
4.3.7
Digital Output
Parameter
Conditions
Min.
Typical
Max.
Units
Output Voltage
Ready, Fault
Operational range
0
5
24
(1)
V
Absolute Max
-
-
28
(1)
eBrake
Operational range
0
-
48
(1)
Absolute Max
-
-
53
(1)
Sourcing Current
(2)
Ready, Fault, eBrake
-
7
-
mA
Sinking Current
Ready, Fault
-
-
2.4
A
eBrake
-
-
1.0
External Load
Impedance
(3)
Ready, Fault
10
-
-
eBrake
48
-
-
(1)
Note:
When voltage is applied externally.
(2)
Note:
When output is "OFF," and output pin is pulled to min operational voltage externally.
(3)
Note:
When output is "ON," and output pin is pulled up to max operational voltage externally.
4.3.8
Analog Input
Parameter
Conditions
Min.
Typical
Max.
Units
Input Voltage
Operational range
-10
-
10
V
Absolute maximum
-12
-
12
Input Impedance
100
-
-
kΩ
4.3.9
Analog Output
Parameter
Conditions
Min.
Typical
Max.
Units
Output Voltage
Operational range
-10
-
10
V
Load impedance
Connected to ground
10
-
-
k
Ω
4.3.10 USB Communications
Parameter
Conditions
Type
USB Interface
USB micro type B female
USB 2.0b
4.3.11 CAN
Parameter
Conditions
Min.
Typical
Max.
Units
CAN Enable Out
Output Voltage
Internal Supply
Operational Range
4.95
5.1
5.25
V
External Supply Absolute Maximum
-
-
5.25
CAN Enable Out
Output Current
Sinking
Absolute Maximum
-
-
200
mA
CAN Enable In+
Input Voltage
CAN Enable In-
pulled to GND
Logic High
3.3
-
-
V
Logic Low
-
-
1
Absolute maximum
-48
-
48