© ElectroCraft 2022
16
High Power Universal Drive User Manual
4
Drive Specifications
Using the drive outside the specified absolute maximum ratings will damage the drive. Using the drive
outside normal operating specifications may not guarantee a reliable operation.
4.1
Physical Specifications
Parameter
Conditions
Typical
Units
Weight
Without mating connectors
250
g
Dimensions
Length x Width x Height
(Without mating connectors)
144.91 x 95.34 x 29.03
mm
5.7 x 3.75 x 1.14
Inch
4.2
Environmental Specifications
Parameter
Conditions
Min.
Typical
Max.
Units
Ambient Temperature
Operating Range
0
-
40
°C
Storage Range
-20
-
85
Ambient Humidity
Non-condensing
5
-
95
%RH
4.3
Electrical Specifications
All ratings at ambient temperatures = 0 to 40°C and PWM frequency of 20 kHz (unless otherwise noted).
4.3.1
DC Supply Input for CPP-A24V80A-SA-CAN
Parameter
Conditions
Min.
Typical
Max.
Units
Supply Voltage
Operating Range
12
-
80
VDC
Absolute maximum
10.5
-
90
Supply Current
Operating at maximum load and speed
-
24
60
A
Idle condition. No
external connections.
@ 12VDC
-
127
-
mA
@ 80VDC
-
24
-
4.3.2
DC Supply Input for CPP-A40V24A-SA-CAN
Parameter
Conditions
Min.
Typical
Max.
Units
Supply Voltage
Operating Range
12
-
24
VDC
Absolute maximum
10.5
-
90
Supply Current
Operating at maximum load and speed
-
40
100
A
Idle condition. No
external connections.
@ 12VDC
-
146
-
mA
@ 24VDC
-
74
-
4.3.3
+5VDC Supply Output
Parameter
Conditions
Min.
Typical
Max.
Units
Output Voltage
Operating Range
5
5.1
5.2
VDC
Output Current
Total combined current on all
connectors
-
-
250
mA