© ElectroCraft 2022
10
High Power Universal Drive User Manual
Installation requirements for EMC CE compliance:
For EMC compliance, correct cable selection and wiring practices are mandatory. The following contains
installation instructions necessary for meeting EMC requirements.
•
Power interface cable that supply power to the drive should not exceed 3m (9.84ft) in length.
•
Motor cables should not exceed 10m (32.8ft) in length without consulting factory. For best results
use ElectroCraft series cables.
•
Shielded cables are mandatory for the motor, power and control cabling to the drive. The power
and motor cables must be bonded to earth at both ends and the control bonded to earth at one
end. The shield of the cable must be grounded at the closed ground point with the least amount
of resistance.
•
Segregate the drive power wiring and motor phase cables from the control wiring and feedback
cabling. When using shielded cables for the power wiring, provide a grounded 360 degree clamp
termination at both ends. Provide for a large contact area between shields and the mounting
plate.
•
The J5 I/O port requires an external ferrite located close to the mating connector, with cable
passing once through the ferrite. Fair-Rite
– 0431176451 or equivalent is required for compliance.
•
Re-install cover for the micro USB type B port (when not in use). The USB enclosure port must be
covered by non-conductive rubber plug, tape or label.
1.6
Life Support Policy
READ THIS ENTIRE SECTION BEFORE ATTEMPTING TO USE THE CPP-A24V80A-SA-CAN DRIVE!
ElectroCraft products are not authorized for use as critical components in life support devices or systems
without the express written approval from ElectroCraft, Incorporated.
1. Life support devices or systems are intended for surgical implant into the body, or support or
sustain life, and whose failure to perform, when properly used in accordance with instructions for
use provided in the User's Manual and in the labeling, can be reasonably expected to result in a
significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system, or to affect
its safety or effectiveness.
1.7
Checking Product on Delivery
When your package arrives, inspect the shipping box and the unit carefully, and save ALL packing
materials. Compare the packing slip against all items included in the shipping box. Any shortages or
other inspection problems should be reported to ElectroCraft immediately.
The following procedure is used to check products upon delivery. Check the following items when your
CPP-A24V80A-SA-CAN or CPP-A40V24A-SA-CAN is delivered.
•
Verify that the model number marked on the nameplate of the drive(s) is the correct model
ordered.
•
Check the overall appearance. Check for damage or scratches that may have occurred during
shipping.