Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8
Output Label
XW15a LF XW15a HF XW15a LF XW15a HF XW15a LF XW15a HF XW15a LF XW15a HF
Output Delay
125us
0s
125us
0s
125us
0s
125us
0s
Polarity Invert
no
no
no
no
no
no
no
no
Output Gain
0dB
-9dB
0dB
-9dB
0dB
-9dB
0dB
-9dB
HP Filter
Type
BW24
LR24
BW24
LR24
BW24
LR24
BW24
LR24
Frequency
50Hz
1.5kHz
50Hz
1.5kHz
50Hz
1.5kHz
50Hz
1.5kHz
LP Filter
Type
LR24
BW12
LR24
BW12
LR24
BW12
LR24
BW12
Frequency
1.5kHz
18.2kHz
1.5kHz
18.2kHz
1.5kHz
18.2kHz
1.5kHz
18.2kHz
All-Pass Filter
Frequency
Slope
out
out
out
out
out
out
out
out
Q
Filter 1
Filter Type
Loshelf
PEQ
Loshelf
PEQ
Loshelf
PEQ
Loshelf
PEQ
Frequency
69.4Hz
1.21kHz
69.4Hz
1.21kHz
69.4Hz
1.21kHz
69.4Hz
1.21kHz
Slope/Q
12dB
4.8
12dB
4.8
12dB
4.8
12dB
4.8
Gain
6dB
3dB
6dB
3dB
6dB
3dB
6dB
3dB
Filter 2
Filter Type
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
Frequency
170Hz
2.67kHz
170Hz
2.67kHz
170Hz
2.67kHz
170Hz
2.67kHz
Q
1.58
3.6
1.58
3.6
1.58
3.6
1.58
3.6
Gain
5dB
4dB
5dB
4dB
5dB
4dB
5dB
4dB
Filter 3
Filter Type
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
Frequency
250Hz
3.74kHz
250Hz
3.74kHz
250Hz
3.74kHz
250Hz
3.74kHz
Q
3.6
4.8
3.6
4.8
3.6
4.8
3.6
4.8
Gain
-3dB
-2dB
-3dB
-2dB
-3dB
-2dB
-3dB
-2dB
Filter 4
Filter Type
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
PEQ
Frequency
2.13kHz
18.2kHz
2.13kHz
18.2kHz
2.13kHz
18.2kHz
2.13kHz
18.2kHz
Q
7.21
1.78
7.21
1.78
7.21
1.78
7.21
1.78
Gain
-4dB
3dB
-4dB
3dB
-4dB
3dB
-4dB
3dB
Filter 5
Filter Type
Frequency
Q
Gain
Filter 6
Filter Type
Hishelf
Hishelf
Hishelf
Hishelf
Frequency
8.79kHz
8.79kHz
8.79kHz
8.79kHz
Slope/Q
12dB
12dB
12dB
12dB
Gain
6dB
6dB
6dB
6dB
Compressor
Threshold (dBu)
Ratio (N to 1)
Insert (In/Out)
out
out
out
out
out
out
out
out
Attack (us)
Release (ms)
Knee (Hard/Soft)
Limiter
Threshold (dBu)
2dBu
-2dBu
2dBu
-2dBu
2dBu
-2dBu
2dBu
-2dBu
Release (ms)
100ms
3ms
100ms
3ms
100ms
3ms
100ms
3ms
XW15a DN9848(e) P3000 0dBu V2.0
Output levels and limiter settings assume equal amplifier power to each passband with amplifier input sensitivity of 0dBu
Notes:
DN9848e and DN9848 with firmware V4.01 and higher have the ability to toggle between Q and BW for parametric filters. DN9848
with firmware V3.05 and older only use BW, use attached conversion spreadsheet to convert. Do not adjust output filters, use input filters for
room and system tuning. DN9848 with firmware V3.05 and older has a maximum of 100ms release time for limiters. For these versions,
change Subwoofer and LF release times to 100ms.